[SOURce[1|2]]:FREQuency:STOP
This command sets or queries the start frequency of sweep for the specified 
channel. This command is always used with the 
[SOURce[1|2]]:FREQuency:STARt command. The setting range of stop 
frequency depends on the waveform selected for sweep. For more information on 
the setting range, refer to the specifications page of Quick Start User Manual.
Group
Source
Related Commands
[SOURce[1|2]]:FREQuency:MODE
[SOURce[1|2]]:FREQuency:STARt
Syntax
[SOURce[1|2]]:FREQuency:STOP {<frequency>|MINimum|MAXimum}
[SOURce[1|2]]:FREQuency:STOP? [MINimum|MAXimum]
Arguments
<frequency>::=<NRf>[<units>]
where
<NRf> is the stop frequency.
<units>::=[Hz | kHz | MHz]
Returns
<frequency>
Examples
SOURce1:FREQuency:STOP 100KHz
sets the stop frequency of CH 1 to 100 kHz.