Patent: ZL 2010 2 0625647.0
Contact Rating
Nominal Load(Resistive Load Cosφ=1)
Contact Capacity
BT90- D.……………..…………….20A/10A at 250VAC
BT90-DM/DB…………………………….30A at 250VAC
Max. Allowable Current
BT90-D....……..…….. …..…………………… ...……20A
BT90-DM/DB ……………………………….…….30A
Max. Allowable Voltage
BT90-D/DM/DB..……………………………… ..AC250V
Max. Allowable Power Force
BT90-D....……....……..…………………...……5,000VA
BT90-DM/DB…………… ……… …… …..…….7,50 0VA
Contact Material……………………………….. Ag Alloy
Contact Form………………………….. …SPDT&SPST
Performance (at Initial Value)
Contact Resistance………….…50mΩ at 6VDC/1A
Operate Time…………………………… .…..1 0ms. Max
Release Time……………………………….... 5ms. Max
Dielectric Strength:
Between Coil & Contact…...…..2,500VAC at 50/60 Hz
for one minute
Between Contacts……...………1,500VAC at 50/60 Hz
for one minute
Surge Resistance………...……10,000V (between Coil
&Contact
1.2x50
μ
s)
Insulation Resistance…….……1,000 MegaΩMin. at
500VDC
Main Feature
1. Small size (31.9x27.5x19.6 in mm) produces a
switching c apacity up to 30A for high densityP.C.Board
mounting technique.
2. The contact form construction is 1A/1B/1C
3. The Surge Resistance of BT90 series is 10,000V
4. Sealing Constructio n (Fre e from dust and solder flux):
BT90-SS:
Plastic Sealed Type.
5. The selection of plastic insulation material is designed
for high temperature and provides better chemical
solution performance.
6. RoHS Compliant.
Application
Air Conditioning, Frid ge, Washing Machine, etc Household
Appliances
Max. On/Off Switching:
Electrical……………………..….…30 Ops per minute
Mechanical…… …… ..………….…300 Ops per minute
Temperat ure Range………………………. . 40~85
Humidity Range……………………………5%~85% RH
Coil Temperature Rise……………... 35 Maxi mu m
Vibration:
Endurance……………………………..10 to 55 Hz dual
amplitude width 1.5mm
Error Operation………………………..10 to 55 Hz dual
amplitude width 1.5mm
Shock:
Endurance………………………………… 981m/s
2
Min
Error Operation…………………...……… 98.1m/s
2
Min
Life Expectancy:
Electrical………………………………10
5
Operations at
Rated Resistive
load
Mechanical……………………………10
7
Operations at
No load condition
Weight………………………………………….about 23g
Safety Standard
Its File Number
UL…………………… ……………………….…E33324 4
TUV…………………………………….…….R50267516
CQC…………………………………CQC11002061851

Summary of content (2 pages)