User's Manual

AR24027 Operator’s Manual (rev A)
- 40 -
display-configuration
source= current or main or alternate or factory
Displays all the parameter values for the specified configuration. If the source is not specified
it defaults to “current”.
Examples:
> display-configuration source=current
> discon
load-configuration
source=main or alternate or factory
Loads the specified configuration into the current set of parameters controlling the radio
operation. If no source is specified it defaults to the “main” configuration.
Examples:
> load-configuration source=factory
> load
lock
This command locks the access to all the commands that can alter the radio configuration.
Once locked use the “unlock” command to regain access to those commands. Note that a
password must be set prior to the “lock” command being issued (the radios are shipped with no
password), otherwise the lock command has no effect. If a password is set, the radio
automatically “locks” the configuration at the end of 10 minutes with no command activity.
save-configuration
destination=main or alternate
Saves the current set of radio operating parameters into one of the two non-volatile
configurations. If the destination is not specified it defaults to main.
Examples:
> save-configuration destination=alternate
> save
unlock
enable-configuration=”ASCII string”
This command, with the correct password, unlocks the access to the commands that allow the
radio configuration to be altered.
Examples:
> unlock enable-configuration=bh7g8