55 000 026 – Ed. B SCOOP E-Z - User Manual 31
This document is the property of AETA and can not be duplicated without authorisation November 2001
9. POTS Information
9.1. Factory default configuration
The Scoop's factory-set default configuration is suitable for most Scoop E-Z
transmission applications and are reloaded by the selected function :
“TOOLS”, “Misc”, ”General reset”.
Your Scoop E-Z is designed to operate over dial-up phone circuits with the following
dialling and call monitor features :
? Multi-frequency signalling (Tone dialling method) or
Loop-disconnect signalling (Pulse dialling method)
Rem :
By issuing the configuration procedure the user can change the
<dialling method> : Pulse or Tone
The selection of the dialling method will be stored until the user has to modify his
choice again even when the Scoop E-Z is power off.
? Operation in the absence of proceed operation (waiting for dial tone)
? Automatic answering
? Originating and answering handshake negotiations begin at the highest DCE line
speed configured in the factory (24 kbps) or at lower speed selected by the menu
with the current configuration.
Automatic speed selection : Handshake negotiations fall back to a lower speed if
necessary.
? Full dial progress detection ( Dial tone detect).
Rem :This parameter must be "disable" for calls originated from Switzerland and
Italy.
Additional setting
? Fall back if negotiation fails at the highest speed ( speed automatic )