Quick Start Guide

SIM ORIENTATION
ALWAYS ensure the system is
switched OFF when adding or
removing your SIM card and ensure
the orientation is correct.
CONNECTION TO NETWORK
4G: Quick Flashing = Standby | Constant ON/OFF = Searching
ALTERNATIVE WIRING EXAMPLE
MODEM LED
INDICATOR
Wiring Connections
( LINKING WITH SECONDARY RELAY IS OPTIONAL )
INTERCOM
SECONDARY
INTERCOM
SECONDARY
MAGNETIC LOCK
STRIKE
LOCK
ALTERNATIVE WIRING EXAMPLE
( LINKING WITH SECONDARY RELAY IS OPTIONAL )
LOCK POWER
SUPPLIES
ARE NOT
INCLUDED AS
PART OF THE
KIT.
CHANGE APN (for VoLTE / 4G services)
SIM
Check with your network provider for the correct APN for 4G data.
Once you have confirmed the APN enter it in place of ‘APNinfo’ in an SMS to the intercom.
via SMS
(if connected to network)
9999#97APNinfo#
Passcode
APN info
for SIM
network
Command
(add APN)
1. Power off the unit, then press and hold the call
button and power the unit on again.
2. Upon power up, a long tone will be emitted from
the speaker and the blue LED will remain solid - it is
now in the APN setting mode.
3. After this, enter the APN serial number through
the keypad then press #.
(e.g. if you want to set APN No. 18, press 1 - 8, then #.
A long beep will again be heard).
4. Reboot unit.
via Keypad (if no 3G signal)
Contact Technical Support or check our resource page
for a list of the APN serial number.
The system will be pre-programmed with the APN for the Tracfone network. If you wish to
use a different network then the correct APN must be set for full operation.
24v DC IN
PB Terminals
Search for
‘APN Flyer PRIME’
Ensure the PCB is powered on and connected
to the network with a GREEN flashing LED.
Then send the below text as an SMS to the
intercom Sim number. A power reboot is
required after the ‘OK’ reply message is
received back.
12-24v
IN
SLAVE IN
1 2 3
12-24v
OUT
SLAVE OUT
1 2 3
IN
12-24v
IN
1 2 3
OUT
1 2 3
OUT
+12v-
SLAVE IN
12-24v
IN
1 2 3
SLAVE OUT
12-24v
OUT
1 2 3
PCB Status LEDs
SOLID RED = PCB POWERED ON
SOLID RED +BLUE FLASHING = SEARCHING
SOLID RED + BLUE FLASHING + GREEN FLASHING = SUCCESSFULLY CONNECTED
DETECT
Gate Position
Limit switch
(optional)
OPEN
Exit Button
(optional)
Relay 1
Relay 2
Tip: All main connections are pre-wired. Below are
optional wiring additions for 3
rd
party controllers.
Keypad
12-24v
IN
SLAVE IN
1 2 3
12-24v
OUT
SLAVE OUT
1 2 3
SLAVE CONNECTIONS
(Optional. Check website for instructions)
PWR | COMMs
Must use a 45 Watt solar panel (minimum)
and at least a 30Amp Hour battery (or two
15Amp Hour batteries for 24V solar.
To Earth
Rod!
24V DC IN
(PSU included)
CellCOM Prime 7 4G
- Advanced GSM Intercom
STILL HAVING TROUBLE?
Find all of our support options such as Web Chat,
Full Manuals, Customer Helpline and more on
our website:
WWW.AESGLOBALUS.COM