Instructions
E. sales@aesglobalus.com
www.aesglobalus.com
T: +1 - 321 - 900 - 4599
Altering XYZ axis
NOTE: We only recommend altering the XYZ axis for complex
sites where you need less activation from a particular
direction, such as the exit road being in close proximity to an
entry road. In this instance we would reduce the X field
direction so that a passing vehicle in next lane will not trigger
the e-Loop.
1. First, make a connection to the e-Loop, then go to MENU
and select Alter Settings and press SET. Now scroll to the
Axis you want to change, then press SET again.
2. If we are changing the X axis, you can set a value between
0% to 200% – this is the same for all X, Y and Z axis.
3. Use the Up or Down arrow buttons to change the value,
then press the SET button to confirm.
NOTE: All values should add up to a minimum of 300, so if
reducing one axis then another should be increased to
compensate.
4. Now press UPLOAD to confirm the new settings and the
screen will display Sending Settings. Then press the CONNECT
button to disconnect the e-Loop, or MENU button to access
other options.
Z = Vertical detection
Y = Approach and Depart detection (Arrow indication)
X = Left and Right-hand side detection
1. Make a connection to the e-Loop, then press MENU and
select Calibrate. The Calibrate menu screen will have
Calibrate Loop highlighted. Now press SET to calibrate
the e-Loop and the screen will display Calibrating Loop.
2. To uncalibrated, the e-Loop enter the Calibrate menu
and scroll down to select Uncalibrate Loop. Now press
the SET button, and the e-Loop is uncalibrated. Use the
Up or Down arrow buttons to change the value, then
press the SET button to confirm.
Calibrating the e-Loop using the diagnostic remote
Radar Read
1. Press SET to read the radar sensor state. If False is
shown it means no object is detected. If True is
displayed this means an object has been detected.