Specifications

40-7170 Revision 2B July 6, 2012
7
2.0 Safety Considerations:
The following items are safety related precautions that you should take into consideration
when installing your AES IntelliNet system. They are for your safety as well as others
and the safety of your equipment.
Use caution when installing antennas to keep them away from electrical wires which
could cause serious injury or death if antenna makes contact with live wires.
All equipment must be installed in accordance with National Electric Code,
applicable UL Standards and local building codes.
Be certain to properly ground the antenna and surge suppressor to help dissipate
surges away from equipment and personnel. The grounding of the antenna and surge
suppressor is for your safety and the safety of your equipment and should not be
neglected.
3.0 Environmental Considerations:
The following environmental related suggestions are to help insure an installation that
will provide you with a system that will operate at its optimum long into the future.
The provided AES 52-0054 surge suppressor should be installed in a weather tight
enclosure such as a UL Listed NEMA4 enclosure.
4.0 Technical Specifications:
Listed below are the technical specifications for the 7170 IP-Link Transceiver.
Transformer Input rating is 16.5 Volts AC at 40/45VA
– Use only provided Model Amseco XF-1640 or ELK P/N ELK-TRG1640 or TDC
Power P/N DA-40-16.5 or MG Electronics P/N MGT1640
DC Current Draw: 370mA standby, 900mA transmit
7170 DC operating voltage
is 12 Volts nominal.
Onboard Fuse; Self
Resetting / Not User
Serviceable
Rechargeable Gel Type
Battery Required:
12V, 10AH
Low Battery Condition, AC
Fail and Charger Trouble
are reported to Central
Station.
Figure C –
Enclosure Dimensions