EMERGENCY PROCEDURES
ENGINE FIRE IN FLIGHT
Close fuel selector
Use remaining fuel (full throttle)
Ignition off
Before landing Master off and Generator off
Note that stall warning will not function
ENGINE FIRE ON GROUND
Do not open engine cover
Use fire extinguisher through exhaust and air inlet
GENERATOR FAILURE
When the Ampere indicator shows discharging (The engine will continue to work):
Check generator circuit breaker
Reduce use of anything that uses electricity
ICING
When RPM drops unexpectedly:
Carburettor heat to full
Full throttle
Seek for non-icing conditions (descend into warmer air)
Expect RPM to drop by 150 RPM and an increase of fuel use.
EMERGENCY LANDING
Check safety belts
Close fuel selector to reduce fire risk
IN CASE OF INVOLUNTA RY SPIN
Elevator and Aileron to neutral
Rudder opposite spin direction
Flaps in