User manual

50 51
50 51
Flaps Position Indicator & Test Switch
1: Flaps position indicator needle
2: Test switch
3: Flaps position lever.
Flaps can be set to the following positions:
0°, 15°, 40°.
In the real aircraft, flaps are infinitely
variable between 0° and 40°. Unfortunately,
this cannot be simulated in MIcrosoft Flight
Simulator, and as this feature is not used
under normal circumstances, it isn´t simulated
in this package.
Ground Clearance Switch
Provides power to the audio panel, COM1 and
NAV1 receivers when pushed. Allows to receive
ATIS and an IFR clearance without the need to
power up the aircraft completely. Avionics Master
Switch and Battery Switch need to be set to OFF
for the Ground Clearance Switch to function
correctly. Ground clearance mode is deactivated
automatically when battery master or external
power are activated.
Static Pressure Source Switch
Abnormal readings of instruments supplied
with static air could indicate a restriction in the
outside static air ports. An alternate source
is provided to supply static air to the pilot´s
instruments from inside the nose section.
Selecting the ALTERNATE SOURCE position of the static pressure selector
valve, disconnects the pilot´s instruments from their normal source and
connects them to the alternate source.