Systems Guide

A318/A319/A320/A321
Professional
SYSTEMS
Systems guide
04-03-49
11 July 2018
OVERHEAD PANEL
TK PUMPS (push button switch), pump the fuel from the wing tanks to the engines.
ON Pump is energized
OFF Pump is deactivated
FAULT When the delivery pressure drops FAULT will be lit in amber, suppressed when OFF
setting is selected
CTR TK XFR (push button switch), pump the fuel from the center tank to the wing tanks
ON XFR valve is open when MODE selector is in MANual mode
OFF XFR valve is closed
FAULT Lit in amber in case of wing tank overflow
MODE SEL (push button switch),
AUTO Center tank XFR is automatic, open when wing tanks are not full, closed when center
tank is empty
MAN Center tank XFR is manually controlled with CTR TK XFRpush button switches
FAULT Lit in amber when:
o Centre tank has more than 250 KG (550 LB) of fuel and the right or left-wing tanks less
than 5000 KG (11000LB). The fault indicates a problem with the fuel transfer or an
incorrect fuel loading
o The MODE selector has been set to MANual
X FEED (push button switch)
OFF Valve closed, no light
ON Valve opens, white ON illuminated
OPEN Green OPEN illuminated
ECAM FUEL SYSTEM DISPLAY