Normal Procedures

A318/A319/A320/A321
Professional
Normal Procedure Guide
02-01-3
10 July 2018
PRELIMINARY COCKPIT PREPARATION (PM DUTY)
EXT PWR (when AVAIL illuminated) .............................................................. ON
APU (when rqrd) ........................................................................................... START
ECAM ............................................................................................................ ON
APU MASTER SW ........................................................................................... ON
ON lt illuminates.
APU page opens on ECAM.
APU START .................................................................................................... ON
FLAP OPEN indication shows.
N and EGT rise.
AT 95%
ECAM APU pages shows AVAIL.
On APU panel START ON lt extinguishes, AVAIL lt illuminates.
After 10 seconds ECAM DOORS page shows.
EXT PWR ....................................................................................................... AS RQRD
May be kept on to reduce APU load.
INT LT ............................................................................................................ AS RQRD
DOCUMENTATION ........................................................................................ ABOARD & CHECK
PARKING BRAKE ............................................................................................ ON
Check BRAKE PRESS indicator. When required use HYD YELLOW PUMP
to recharge.
FLAPS ............................................................................................................ CHECK POSITION
Confirm flap handle position and ECAM display in agreement.
SPEED BRAKE ................................................................................................ CHECK RETRACTED
Confirm speed brake handle position and ECAM display in agreement.
ECAM RCL ...................................................................................................... DEPRESS
Depress recall button for 3 seconds to recall and clear all messages
ECAM HYD ..................................................................................................... CHECK
Check for abnormal indications
ECAM ENG..................................................................................................... CHECK
Check for abnormal indications
APU BLEED .................................................................................................... AS RQRD
Select on when needed for air conditioning
X-BLEED ......................................................................................................... AUTO
ZONE TEMP SELECTORS ................................................................................. .AS RQRD