Normal Procedures
A318/A319/A320/A321
Professional
Normal Procedure Guide
Vol
2
02-01-3
10 July 2018
PRELIMINARY COCKPIT PREPARATION (PM DUTY)
EXT PWR (when AVAIL illuminated) .............................................................. ON
APU (when rqrd) ........................................................................................... START
ECAM ............................................................................................................ ON
APU MASTER SW ........................................................................................... ON
• ON lt illuminates.
• APU page opens on ECAM.
APU START .................................................................................................... ON
• FLAP OPEN indication shows.
• N and EGT rise.
AT 95%
• ECAM APU pages shows AVAIL.
• On APU panel START ON lt extinguishes, AVAIL lt illuminates.
• After 10 seconds ECAM DOORS page shows.
EXT PWR ....................................................................................................... AS RQRD
• May be kept on to reduce APU load.
INT LT ............................................................................................................ AS RQRD
DOCUMENTATION ........................................................................................ ABOARD & CHECK
PARKING BRAKE ............................................................................................ ON
• Check BRAKE PRESS indicator. When required use HYD YELLOW PUMP
to recharge.
FLAPS ............................................................................................................ CHECK POSITION
• Confirm flap handle position and ECAM display in agreement.
SPEED BRAKE ................................................................................................ CHECK RETRACTED
• Confirm speed brake handle position and ECAM display in agreement.
ECAM RCL ...................................................................................................... DEPRESS
• Depress recall button for 3 seconds to recall and clear all messages
ECAM HYD ..................................................................................................... CHECK
• Check for abnormal indications
ECAM ENG..................................................................................................... CHECK
• Check for abnormal indications
APU BLEED .................................................................................................... AS RQRD
• Select on when needed for air conditioning
X-BLEED ......................................................................................................... AUTO
ZONE TEMP SELECTORS ................................................................................. .AS RQRD