Table 3-24. Maintenance System Tests Page
Field/Control
Description
Current Bit Pattern – Bit pattern to use in
BER test
Current Test Length – The current length
of time the test executes.
Current Num Of Symbols – Displays the
current number of symbols in a frame to
use for test execution.
BER Status – Status of test
o Not Running
o Running as Master
o Running as Slave
Time left – Displays a countdown for the
length of the test, if the length is “Until
Stopped” this field displays a “∞” symbol
4
BER Test
Bit Error Rate Test requires a unit configured as
the master and a unit configured as the slave for
proper execution and results.
Mod Type – Allows the administrator to
change the modulation for test execution.
The drop down list provides the
selections.
Set button – Changes the modulation to
the value chosen from the Mod Type drop
down list.
Bit Pattern – Allows the administrator to
select a new bit pattern for test execution.
The drop down list provides the
selections.
Set button – Changes the bit pattern to the
value chosen from the Bit Pattern drop
down list.
Test Length – Allows the administrator to
select a new test length. The drop down
list provides the selections.
Set button - Changes the test execution
length to the value chosen from the Test
Length drop down list.
Symbols (0 –122) – Allows the
administrator to provide a new number of
symbols for test execution. The
configured numbers of symbols much
match on the master and slave.
BER Status – Displays the current state of
the test.
o Not Running
o Running as Master
o Running as Slave