User's Guide

Form #: OP_01_TM
Title: Aeronix Data Links – EDL Nano Products User Guide
Document Number: AE301628-001
Revision: B Date: 3 October 2019
Aeronix Proprietary
85
Figure 3-60 OFDM Maintenance System Tests Page
Table 3-24. Maintenance System Tests Page
Field/Control
Description
1
System Information
Current Channel – Displays the current
channel and frequency of the unit. This
defines the channel where test execution
occurs.
2
CW Test
Continuous Sine Wave Test
CW Status – Displays the state of the test
o Not Running
o Transmitting…
o Receiving…(RSSI x )
if actually receiving a CW then the
RSSI level is displayed
Start Transmit button – Starts the CW
transmission
Start Receive button – Puts the unit in
receive mode to capture the CW
transmission from another unit.
Stop All Tests – Stop the test from running
and returns the unit to normal operation.
3
BER Test
Current settings
Current Mod Type - Displays the current
modulation setting for test execution.
1
6
2
3
4
5