70
Table 3-19. Subscriber Profile Config Page
Field
Description
CINR/SNR Minimum Entry - Defines the CINR/SNR
value in dBm at which ACM allows entry into to the
FEC code type.
FEC Mandatory Exit - Defines the largest number of
FEC bits one symbol can have before the decision is
made to move out of the current FEC code type.
FEC Minimum Entry - Defines the largest number of
FEC bits one symbol can have before ACM attempts
to move to a higher data per symbol FEC Code type.
Available - symbol FEC Code type.
Available – Displays the availability of the burst
profile. Enabled profiles are used in the ACM
scheme and disabled profiles are not used.
2
Upstream
Burst Profiles
The upstream burst profiles are displayed for
informational and debug purposes. The upstream burst
profiles use the same FEC code types and entry and
exit thresholds defined for the downstream burst
profiles.
3.6.12. Subscriber Station Radio Control Page