User's Guide
Form #: OP_01_TM
Title: Aeronix Data Links – EDL Nano Products User Guide
Document Number: AE301628-001
Revision: B Date: 3 October 2019
Aeronix Proprietary
61
Table 3-14. Base Station Video Page
Field/Control
Description
Raw Buffer > 0, and Raw Timeout = 0 – The
serial will buffer bytes until the number of
bytes on the serial match the Raw Buffer
bytes and then the data will be packaged
into a UDP packet and sent.
Raw Buffer = 0 and Raw Timeout > 0 – The
serial will buffer the amount of bytes in the
amount of time specified by the Raw
Timeout. The timer is started at each
interval, ie not when the first byte is
received.
Raw Buffer = 0, and Raw Timeout = 0 –
This will package up a byte as it is received
from the serial.
Disable/Enable Flow Radio Buttons – Allows
user to disable or enable the serial flow control
Submit Button – Once submitted all of the above
changes will take effect
3.6.8. Subscriber Station Status
When the GUI is accessed using an approved browser, the unauthenticated status page is
displayed.
Figure 3-45 SS OFDM Status Page
4
2
1
3