User's Guide

Form #: OP_01_TM
Title: Aeronix Data Links – EDL Nano Products User Guide
Document Number: AE301628-001
Revision: B Date: 3 October 2019
Aeronix Proprietary
60
Table 3-14. Base Station Video Page
Field/Control
Description
o Rx Only – Receive data from designated
receive port and push the data out to
serial B
o Tx Only – Transmit data from serial B to
designated destination IP address and
IP port
o Both (Rx and Tx) – Radio will push data
from its Serial B to an external node with
the destination IP address and IP Port
configured at GUI. The radio will also
receive data from receive port and send
that data to its Serial B.
3
Serial Flow
Control
Configuration
Serial Baud Rate – A drop down menu with a
selection of baud rates available.
Serial Raw Mode
Enable – Enables Raw mode and serial B
will process serial input in non-canonical
mode.
Disable – Serial B will be set in canonical
mode. This will enable line processing mode
and each line designated by a new line. The
entire line will be wrapped into a UDP
packet and then sent across the RF link.
Destination Port – Ability to set the port that the
BS serial data is being transmitted on.
Receive Port – Ability to set the port that the BS
is receiving serial data on.
Destination IP Addr – Ability to set the Radio’s
IP address that the serial data is being
transmitted to and received from.
Raw Serial mode processing configurations
Raw Buffer – in bytes, the maximum is 255
bytes.
Raw Timeout ( deci seconds) - in tenths of
seconds, maximum is 255 deci seconds.
When in Raw mode the user can configure the
serial to buffer bytes and to be more efficient
than sending just one character, below are the
valid configurations.
Raw Buffer > 0 Raw and Timeout > 0 – The
serial will buffer the bytes until the first
condition is met and then the data will be
packaged into a UDP packet and sent. The
timer will be started when the first byte is
received.