Table 3-13. Base Station Maintenance Page
Field/Control
Description
Current RSSI – Displays the
instantaneous RSSI at the preamble for
the connection.
Average RSSI – Displays the average
RSSI at the preamble of the connection
over a period of received frames.
Current Mod Type – Displays the current
modulation type received by the BS. This
represents the modulation of the SS
transmissions.
Curr Freq Offset (Hz) – Displays the
frequency offset at the time of the display
update.
Avg Frequency Offset (Hz) – Displays the
average frequency offset of the
connection over a period of received
frames.
FEC Corrected Bits – Displays the
instantaneous forward error correction
corrected bits.
Average FEC Corrected Bits – Displays
the average forward error correction
corrected bits over a period of received
frames.
Reed-Solomon Symbol Errors Cur –
Displays the instantaneous number of
Reed-Solomon errors.
Reed-Solomon Symbol Errors Avg –
Displays the average Reed-Solomon
errors over a period of received frames.
Time of Arrive Difference – Displays the
offset in time of when the BS expected to
receive a burst and when it actually
received a burst.
CP Offset Cur – Displays the
instantaneous cyclic prefix offset. This
offset refers to where the FFT is
positioned in the symbol.
CP Offset Avg – Displays the average CP
offset over a period of received frames.
7
Alarm Interrupts
Temperature Protect –Provides a count of
how many times the RF Temperature
reached 83° C. When the he RF
temperature reaches 83° C, the software
will disable the RF Transmit and Receive.
When RF temperature lowers to 65°C, the