14
Figure 3-1 BS GMSK Status
Table 3-1. Base Station Status Page
Field/Control
Description
1
Status
Status displays a subset of current settings.
MAC Address – The IEEE 802.16 MAC address
of the base station
Current Channelization – Displays the
channelization of the base station. The
channelization may be changed on the Radio
Control Screen.
Current Channel – The current 802.16 specified
channel that the base station uses for transmit
and receive. The channel may be changed on
the Radio Control screen.
BS Estimated EIRP – Displays the estimated
EIRP of the base station based upon user
configured gain a loss values. (Est Tx Pwr +
Antenna Gain – External Tx Cable Loss –
Antennal Cable Loss – Internal Tx Loss )
Tx - Provides the status of the transmit portion of
the unit. (On/Off) The status may be changed
on the Radio Control screen.
Rx - Provides the status of the receive portion of
the unit. (On/Off) The status may be changed
on the Radio Control screen.
Transec Status – Displays the status of Transec
(on or off). The Transec status can be changed
on the Admin Screen.
2
Board Details
Display Temperature
CPU Temperature – Displays the temperature
reported by the processor in Celsius and
Fahrenheit
RF Temperature – Displays the temperature
reported by the AD9361 chip on the RF card in
Celsius and Fahrenheit
3
Front Panel
Displays PHY status on an interval basis.
Base is a constant green light if the radio is
configured as a Base Station
Sync is off on the base station when no
subscribers are registered and is illuminated
continuously when subscribers are registered.
Recv is green when the radio is receiving
messages
Xmit is green when the radio is transmitting data
Alarm