User's Guide

Form #: OP_01_TM
Title: Aeronix Data Links – EDL Nano Products User Guide
Document Number: AE301628-001
Revision: B Date: 3 October 2019
Aeronix Proprietary
164
"Table 362, in IEEE Std 802.16-2004"
::= { wmanIfBsOfdmDcdBurstProfileEntry 5 }
wmanIfCmnOfdmDiucFecMandatoryExitThresh OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DIUC mandatory exit threshold: 0 - 63.75 dB CINR at or
below where this DIUC can no longer be used and where this
change to a more robust DIUC is required in 0.25 dB units."
REFERENCE
"Table 362, in IEEE Std 802.16-2004"
::= { wmanIfBsOfdmDcdBurstProfileEntry 6 }
wmanIfCmnOfdmDiucFecMinEntryThresh OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DIUC minimum entry threshold: 0 - 63.75 dB The minimum CINR
required to start using this DIUC when changing from a more
robust DIUC is required, in 0.25 dB units."
REFERENCE
"Table 362, in IEEE Std 802.16-2004"
::= { wmanIfBsOfdmDcdBurstProfileEntry 7 }
wmanIfCmnOfdmAvailableType OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
""
::= { wmanIfBsOfdmDcdBurstProfileEntry 8 }
wmanIfCmnOfdmDcdBurstProfilerowStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object is used to create a new row or modify or
delete an existing row in this table.
If the implementator of this MIB has choosen not
to implement 'dynamic assignment' of profiles, this
object is not useful and should return noSuchName
upon SNMP request."
::= { wmanIfBsOfdmDcdBurstProfileEntry 9 }
--
--
--
--