wmanIfCmnOfdmDcdBurstProfIndex OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The Downlink Interval Usage Code indicates the downlink
burst profile in the DCD message, and is used along with
ifIndex to identify an entry in the
wmanIfCmnOfdmDcdBurstProfileTable."
REFERENCE
"Subclause 8.3.6.3.1, in IEEE Std 802.16-2004"
::= { wmanIfBsOfdmDcdBurstProfileEntry 1 }
wmanIfCmnOfdmDiucValue OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-only
STATUS current
DESCRIPTION
""
::= { wmanIfBsOfdmDcdBurstProfileEntry 2 }
wmanIfCmnOfdmDcdFecCodeType OBJECT-TYPE
SYNTAX WmanIfOfdmFecCodeType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Downlink FEC code type and modulation type"
REFERENCE
"Table 362, in IEEE Std 802.16-2004"
::= { wmanIfBsOfdmDcdBurstProfileEntry 3 }
wmanIfCmnOfdmDiucCinrMandatoryExitThresh OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DIUC mandatory exit threshold: 0 - 63.75 dB CINR at or
below where this DIUC can no longer be used and where this
change to a more robust DIUC is required in 0.25 dB units."
REFERENCE
"Table 362, in IEEE Std 802.16-2004"
::= { wmanIfBsOfdmDcdBurstProfileEntry 4 }
wmanIfCmnOfdmDiucCinrMinEntryThresh OBJECT-TYPE
SYNTAX INTEGER
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"DIUC minimum entry threshold: 0 - 63.75 dB The minimum CINR
required to start using this DIUC when changing from a more
robust DIUC is required, in 0.25 dB units."