At this point the subscriber should register with the base station if it is powered on, on the
same channel (frequency), has the same TRANSEC state and key, Tx/Rx is on and has the
same channelization.
Add the classifiers for the new service flows so that data can pass to and from the
subscriber:
1. Browse to the Network Config page of the base station.
2. Click on the Auto Populate button in the Class Rules section.
3. Provide the proper Station IP and Station Mask for each entry in the table.
a. Station IP BS – 192.168.100.1 Station Mask – 255.255.255.0
b. Station IP SS1 – 192.168.1.1 Station Mask – 255.255.255.0
c. Station IP SS2 – 192.168.2.1 Station Mask – 255.255.255.0
d. Station IP SS3 – 192.168.3.1 Station Mask – 255.255.255.0
4. Click the Generate Classifiers button at the bottom of the class rules table.