13 GR-UT699 Development Board
User Manual
2.4.1 Configuration of Bus Termination
The CAN interfaces on the board can be configured for either end node or stub-node
operation by means of the jumpers JP3 and JP4 for interface 1 and 2 respectively, as shown
in Figure 2-5.
For normal end-node termination with a nominal 120 Ohm insert jumpers in position 1-3.
However, if a split termination is desired (if required for improved EMC performance), insert
the jumpers in positions 1-2 and 3-4.
For stub nodes, if termination is not required, do not install any jumpers.
© Aeroflex Gaisler AB March 2013, Rev. 0.6