RF spectrum analyzer
Frequency Range 400 kHz to 1.05 GHz
Spans Continuously variable,
1 kHz / division to 100 MHz / division
1,2,5,10 increments
Start / Stop frequency entry
Resolution Bandwidth 300 Hz, 3, 30, 300 kHz, 3 MHz
Reference Level (top of screen) 50 dBm to +52 dBm, 0.7 mV to 71 V
Displayed dynamic range 80 dB
Noise floor Typically 75 dB below top of screen
On screen linearity Typically ± 2 dB ±1 resolution (10 dB/div)
(10 dB above the noise floor)
Vertical resolution 0.1 dB on 2 dB / division
0.5 dB on 10 dB / division
Level Flatness ± 2 dB ±resolution (10 dB/division)
Intermodulation Distortion Better than 70 dB for two signals at 30 dBm into first mixer
Sweep speeds 10 ms/div to 200 ms/div in a 1, 2, 5 sequence (optimum sweep
speed and bandwidth selected according to span)
SPAN
RES B/W UPDATE
10 kHz
300 Hz 5 SWEEP/sec
100 kHz
3 kHz 9 SWEEP/sec
1 MHz
30 kHz 9 SWEEP/sec
10 MHz
300 kHz 9 SWEEP/sec
100 MHz
300 kHz 5 SWEEP/sec
1000 MHz
3 MHz 5 SWEEP/sec
Marker Indication Level and frequency or delta marker from center line of screen
Single marker for frequency and level display
Marker to center frequency marker
Features Simultaneous 'Look and Listen'
Span 100 kHz, 200 kHz, 500 kHz, 1 MHz
Sensitivity 2 μV
Tracking Generator Offset/Frequency
Range
0-999 MHz/400 kHz to 1 GHz