Operating instructions

GENERAL INFORMATION
1-7
Performance data
Receiver measurements
RF signal generator
Frequency
Range 400 kHz to 1.05 GHz
Resolution 10 Hz
Indication 10 digit display
Setting Keyboard entry, delta increment / decrement function and rotary
control
Accuracy As frequency standard
Output Level
Range Rx Test:
N-Type socket: 141 dBm to 21 dBm
BNC socket: 115 dBm to +5 dBm (usable to +7 dBm)
Resolution 0.1 dB
Indication 4 digits plus sign (dBm, dBμV, μV, mV, PD/EMF).
Accuracy ± 2 dB for level above 127 dBm on N-Type socket up to 1 GHz
Attenuator Hold Facility
Allows user to define start point for seamless generator operation
across a range of up to 20 dB (guaranteed 10 dB minimum).
CW and FM modes only
Reverse Power Protection
N-Type: 50 W for 10 minutes, normal operation. 150 W for 1 minute
at 20°C.
Overload indicated by audible and visual warning.
BNC: 5 W Tripping indicated by audible and visual warning.
Output Impedance Nominally 50 Ω
VSWR N-Type Better than 1.2:1 up to 500 MHz
Better than 1.35:1 up to 1.05 GHz
VSWR BNC Better than 2.2:1 up to 1.05 GHz
Spectral Purity
Residual FM Less than 6 Hz RMS (0.3 to 3.4 kHz) <500 MHz
Less than 12 Hz RMS (0.3 to 3.4 kHz)
Harmonics Better than 25 dBc
Spurious signals Better than 50 dBc
SSB phase noise (20 kHz offset) Better than 112 dBc / Hz <500 MHz
Better than 108 dBc / Hz up to 1 GHz
RF carrier leakage Less than 0.5 μV PD generated in a 50 Ω load by a 2 turn loop 25 mm
from the case. Output level less than 40 dBm into a sealed 50 Ω
load.