Operating instructions

DIRECTIONAL POWER HEADS
A-13
Table A-1 Conversion of VSWR to return loss
VSWR Return
loss
(dB)
VSWR Return
loss
(dB)
VSWR Return
loss
(dB)
VSWR Return
loss
(dB)
1.00
1.21 20.4 1.54 13.4 1.96 9.8
1.01 46.1 1.22 20.1 1.56 13.2 1.98 9.7
1.02 40.1 1.23 19.7 1.58 13.0 2.00 9.5
1.03 36.6 1.24 19.4 1.60 12.7 2.50 7.4
1.04 34.2 1.25 19.1 1.62 12.5 3.00 6.0
1.05 32.3 1.26 18.8 1.64 12.3 3.50 5.1
1.06 30.7 1.27 18.5 1.66 12.1 4.00 4.4
1.07 29.4 1.28 18.2 1.68 11.9 4.50 3.9
1.08 28.3 1.29 17.9 1.70 11.7 5.00 3.5
1.09 27.3 1.30 17.7 1.72 11.5 5.50 3.2
1.10 26.4 1.32 17.2 1.74 11.4 6.00 2.9
1.11 25.7 1.34 16.8 1.76 11.2 6.50 2.7
1.12 24.9 1.36 16.3 1.78 11.0 7.00 2.5
1.13 24.3 1.38 15.9 1.80 10.9 7.50 2.3
1.14 23.7 1.40 15.6 1.82 10.7 8.00 2.2
1.15 23.1 1.42 15.2 1.84 10.6 8.50 2.1
1.16 22.6 1.44 14.9 1.86 10.4 9.00 1.9
1.17 22.1 1.46 14.6 1.88 10.3 9.50 1.8
1.18 21.7 1.48 14.3 1.90 10.2 10.00 1.7
1.19 21.2 1.50 14.0 1.92 10.0 11.00 1.6
1.20 20.8 1.52 13.7 1.94 9.9
Additional parts associated with directional power head
Supplied
Part no.
Lead Assembly with DIN plugs, 3 m 43130/591
Carrying Case HF version 46662/190
Carrying Case UHF version 46662/189
Optional
Lead Assembly with DIN plugs, 1 m 43130/590
Dual DIN Connector Assembly 44990/814