Operating instructions
ACCEPTANCE TESTING
5-33
Results table 5-5 ALC linearity at 1000 MHz
Level
(dBm)
Lower
limit
Upper
limit
Result
−21 −23.0 −19.0
_______
−22 −24.0 −20.0
_______
−23 −25.0 −21.0
_______
−24 −26.0 −22.0
_______
−25 −27.0 −23.0
_______
−26 −28.0 −24.0
_______
−27 −29.0 −25.0
_______
−28 −30.0 −26.0
_______
−29 −31.0 −27.0
_______
−30 −32.0 −28.0
_______
−31 −33.0 −29.0
_______
−32 −34.0 −30.0
_______
−33 −35.0 −31.0
_______
−34 −36.0 −32.0
_______
−35 −37.0 −33.0
_______
−36 −38.0 −34.0
_______
−37 −39.0 −35.0
_______
−38 −40.0 −36.0
_______
Results table 5-6 Carrier harmonic test points at 0 dBm
Frequency
(MHz)
Second
harmonic
(MHz)
Result Third
harmonic
(MHz)
Result Upper
limit
(dBc)
0.4 0.8 _______ 1.2 _______
−25
100.0 200.0 _______ 300.0 _______
−25
300.0 600.0 _______ 900.0 _______
−25
500.0 1000.0 _______ 1500.0 _______
−25
700.0 1400.0 _______ 2100.0 _______
−25
900.0 1800.0 _______ 2700.0 _______
−25
1000.0 2000.0 _______ 3000.0 _______
−25
Results table 5-7 Spurious signals (carrier at 0 dBm)
Carrier
frequency
(MHz)
Spurious
measured
Upper
limit (dBc)
0.4 _______
−50
500 _______
−50
1000 _______
−50
650 _______
−50