Operating instructions

ACCEPTANCE TESTING
5-6
RF output level
Specification
Level range:
141 dBm to 21 dBm (N-type socket)
Accuracy:
± 2 dB up to 1 GHz
Test equipment
Description Minimum specification Example
RF power meter
± 0.1 dB from 10 MHz to 1 GHz
IFR 6960/A/B +
6920 sensor
Measuring receiver
21 dBm to 127 dBm, 2.5 MHz to 1 GHz
HP 8902A +
11772A sensor
Spectrum analyzer
Noise floor < 127 dBm
IFR 2383
RF power meter
C2581
UUT
N TYPE
OUTPUT
SENSOR
INPUT
6920
Fig. 5-2 RF level set up
(1) Refer to Results table 5-2 on page 5-31. C
onnect the sensor to the UUT N-type output
socket
, as shown in Fig. 5-2.
(2) Set the UUT to [Rx TEST], RF IN/OUT [SELECT] N-type output/antenna input mode,
[RF Gen], [ LEVEL] 21 dBm, [ FREQ] 10 MHz. All modulation and noise measurements
should be switched OFF.
(3) Check that the power meter indicates 21 dBm ± 2 dB.
(4) Select N-type output/N-type input mode and check that the level measured is
21 dBm ±2 dB.
(5) Press RF IN/OUT [SELECT] until the mode returns to N-type output/antenna input.
(6) Repeat steps 3 to 5 for 100 MHz and then in 100 MHz steps up to and including 1000 MHz.
ALC linearity
(1) Refer to Results table 5-3 on page 5-32. Connect the sensor to the N-type output socket, as
shown in Fig. 5-2.
(2) Set the UUT to [RF Gen], [LEVEL] 21 dBm, [Δ INC] 1 dB, [FREQ] 10 MHz.
(3) Increment the RF output of the UUT in 1 dB steps down to 38 dBm, ensuring that the
indication on the power meter is within ±2 dB of each level set.
(4) Return the UUT RF level to 21 dBm.
(5) Set the UUT carrier frequency to 500 MHz and repeat step 3. Refer to Results table 5-4 on
page 5-32.
(6
)
Set the UUT carrier frequency to 1 GHz, return the level to 21 dBm and repeat step 3.
Refer to Results table 5-5 on page 5-33.