Specifications
4
Be Cool! Be Aerocool!
5. Efficiency versus Load
Strike
-
X 500/600W Efficiency
Loading
100%
50%
20%
Efficiency
82
%
8
5
%
82%
PFC
≧
0.9 -- --
Strike
-
X 800W Efficiency
Loading
100%
Load
50%
Load
20%
Load
Efficiency
82
%
8
5
%
82%
PFC
≧
0.9
--
--
Strike
-
X 1100W Efficiency
Loading
100%
Load
50%
Load
20%
Load
Efficiency
82
%
8
5
%
82%
PFC
≧
0.9
--
--
6. DC Output Ripple & Noise
Parameter
Ripple
+
Noise
Units
+5V 50 mV
+12V1 120 mV
+12V2 120 mV
-12V 120 mV
+3.3V 50 mV
+5Vsb 50 mV
7. Output Protection
7
.1
Over Voltage Protection
The +5V/+12V/+3.3V DC output are protected against the over voltage
condition. Maximum value can't be over 6.5V at 5V terminal and 15.5V at
12V, 4.3V at 3.3V.