Specifications

80 PLUS Verification and Testing Report
TYPICAL EFFICIENCY (50% Load):
90.09%
AVERAGE EFFICIENCY :
88.48%
80 PLUS COMPLIANT:
YES
Value
Units
115-230 Volts
15 Amps
0.00 Hz
1100 Watts
Note: All measurements were taken with input voltage at 115 V nominal and 60 Hz. Input AC Current Waveform (ITHD = 5.65%, 50% Load)
I
RMS
PF
A
-12V
3.3V
5V
5Vsb
2.26 0.99 8.85% 20%
Light
256.60 11.7/0 3.4/2.3 5/2.9 5.2/0.4 225.62
87.93%
5.44 1.00 5.65% 50%
Typical
623.70 11.7/0.1 3.4/5.7 5/7.1 5.1/0.9 561.90
90.09%
11.09 1.00 3.94% 100%
Full
1274.50 11.8/0.3 3.3/11.3 4.9/14.2 5/1.8 1114.10
87.41%
Rated Output Power
I
THD
(%) Load
(%)
12V (cumulative of 12V1, 12V2, etc.)
Fraction
of Load
DC Terminal Voltage (V)/ DC Load Current (A)
Output
Watts
12.2/81.7
12.2/40.9
Input
Watts
12.3/16.4
Efficiency
%
Test Date
Input Frequency
2637
Type
Ecos ID #
Model Number
6/30/2011
2011
Input Current
Serial Number
Aerocool
STRIKE-X1100
N/A
Manufacturer
Year
ATX12V
Rated Specifications
Input Voltage
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
0%
25%
50%
75%
100%
125%
Efficiency (%)
Efficiency of the Power Supply
Efficiency %
Input Watts
Output Watts
0.00
200.00
400.00
600.00
800.00
1000.00
1200.00
1400.00
20%
50%
100%
Power (Watts)
Input and Output Power
-10
-8
-6
-4
-2
0
2
4
6
8
10
-200
-150
-100
-50
0
50
100
150
200
0 0.003 0.006 0.009 0.012 0.015
Current (A)
Voltage (V)
Time (s)
Input Current and Voltage Waveforms
Voltage Current
0%
25%
50%
75%
100%
125%
Loading (% of Rated Output Power)
20%
50%
100%
Loading (% of Rated Output Power)
These tests were conducted by a third party independent testing firm on
behalf of the 80 PLUS Program. 80 PLUS is a certification program to
promote highly-efficient power supplies (greater than 80% efficiency in the
active mode) in technology applications. http://www.80plus.org/