Model: AP904 H-SL Series
4” Duct
Static Pressure (inches w.g.)
0.1
0.25
Air Volume (CFM)
90
73
Noise (sones)
0.3
n/a
Power Consumption (Watts)
33
32.3
Energy Efficiency (CFM/Watts)
2.7
2. 2
Current (AMPS)
0.4
0.36
Grille Dimensions
13 3/8’ x 13 3/8”
Model
Qty
Comments
Project
Location
Architect
Engineer
Contractor
Submitted by
Date
Specifications
AP 904 H-SL SERIES
Slim Fit Bathroom Fan with 10W 4000K LED Light
and Integrated Humidity Sensor
ETL Listed for installation over tub/shower enclosure with
GFCI circuit wiring.
Description: Slim fit bathroom fan with 10W 4000K 1150
Lumens dimmable LED light engineered for continuous run
Integrated user adjustable humidity sensor Ceiling mount
Suitable for new construction or remodeling HVI certified
ETL listed for use in insulated ceilings (Type I.C.).
Motor/Blower: Permanently lubricated enclosed condenser motor
engineered for continuous energy efficient operation; power rating
120v/60Hz; motor equipped with thermal shut off.
Housing: Rugged 26 GA galvanized steel; detachable 4 and 6” duct
connector with built-in back draft dampener; 2 anti-vibration hangar
bar brackets adjustable to 24” span included; designed for ceilings
with a minimum of 6” clearance.
Grille: Contemporary design; low maintenance, wipe clean UV
inhibiting polymeric resin; attaches to housing with torsion springs.
Finishes: White (W); Satin Nickel (SN); Oil Rubbed Bronze (OR).
Light: 10W 4000K 1150 Lumens dimmable LED light.
User-Adjustable Integrated Sensor: Humidity sensor adjustable from
50-100% relative humidity (RH).
Installation: Must be installed by a licensed professional. Complete
installation instructions included.
Warranty: 6 Years
Architect’s Specifications: Ventilation fan will be ceiling mount
and no more than 0.3 sones at 90 CFM as certified by HVI at 0.1 Ps
(inches water gauge). Power consumption shall be no greater than 33
watts with an efficiency rating of no less than 2.7 CFM/watt. Light
shall be 10W 4000K dimmable LED light pad The motor will be
permanently lubricated, engineered for continuous operation. Duct
diameter will be 4” or 6” round. Fan will begin operation when
humidity rises above user adjustable setpoint (50-100% RH). Fan
shall be ETL/cETL listed for tub/shower enclosure when used with
GFCI branch circuit wiring and shall be ETL/cETL listed for use in
insulated ceiling (Type I.C.).