Model: AP120 S G6 Series 
6” Duct 
Static Pressure (inches w.g.) 
0.1 
0.25 
Air Volume (CFM) 
126 
111 
Noise (sones) 
0.7 
n/a 
Power Consumption (Watts) 
33 
32.3 
Energy Efficiency (CFM/Watts) 
3.8 
3.4 
Current (AMPS) 
0.28 
0.27 
ENERGY STAR rated 
Yes 
Grille Dimensions 
13 3/8’ x 13 3/8” 
Model 
Qty 
Comments 
Project 
Location 
Architect 
Engineer 
Contractor 
Submitted by  
Date 
Specifications 
AP120-S G6 SERIES 
Very Quiet Slim Fit Bathroom Fan 
ETL Listed for installation over tub/shower enclosure with 
GFCI circuit wiring. 
Description:  Super quiet slim fit bathroom  fan engineered for 
continuous  run    Ceiling  or  wall  mount  Suitable  for  new 
construction or remodeling  HVI certified  ENERGY STAR 
qualified  ETL listed for use in insulated ceilings (Type I.C.).  
Motor/Blower:  Permanently  lubricated  enclosed  condenser 
motor  engineered  for  continuous  energy  efficient  operation; 
power rating 120v/60Hz; motor equipped with thermal shut off. 
Housing:  Rugged  26  GA  galvanized  steel;  2  anti-vibration 
hangar  bar  brackets  adjustable  to  24”  span  included;  designed 
for ceilings with a minimum of 6” clearance. 
Duct: Detachable 4” and 6” duct connector with built-in back draft 
dampener. 
Grille:  Contemporary  design; low maintenance, wipe  clean UV 
inhibiting  polymeric  resin;  attaches  to  housing  with  torsion 
springs. 
Finishes: White  (W);  Satin  Nickel (SN);  Oil Rubbed  Bronze 
(OR). 
Installation:  Must  be  installed  by  a  licensed  professional. 
Complete installation instructions included. 
Warranty: 6 Years 
Architect’s  Specifications: Ventilation  fan will  be ceiling or 
wall  mount,  ENERGY  STAR  qualified  and  no  more  than  0.7 
sones  at  120  CFM  as  certified  by  HVI  at  0.1  Ps  (inches  water 
gauge).  Power  consumption  shall  be  no  greater  than  33  watts 
and ENERGY STAR rated with an efficiency rating of no less 
than 3.8 CFM/watt. The motor will be permanently lubricated, 
engineered  for  continuous  operation. Duct  diameter  will be  6” 
round. Fan shall be ETL/cETL listed for tub/shower enclosure 
when  used  with  GFCI  branch  circuit  wiring  and  shall  be 
ETL/cETL  listed  for  use  in  insulated  ceiling    (Type  I.C.).  Fan 
shall be ASHRAE 62.2, LEED, CalGreen, and WA Ventilation 
Code compliant.        
Aero Pure, LLC    1006 Bankton Circle Ste B     Hanahan, SC 29410     843.377.8642 