Operation Manual
96
OPERATIONAL PERFORMANCE (continued)
Power:
Battery 1 - 3 vdc, type CR2450 Lithium battery
Shelf life Up to 5 years
Replacement User replaceable (annual recommended)
Life expectancy 100 dive hours (if 1 - 1 hour dive per dive day) to over
300 dive hours (if 3 - 1 hour dives per dive day)
Activation:
Manual - push button (recommended)
Automatic - by immersion in water (if Wet Activation is set ON)
H2O graphic indicates Wet Contacts are bridged (unit must be dried prior to transport or storage).
Cannot be manually activated deeper than 4 feet (1.2 meters), if the Wet Activation feature is set OFF.
Cannot be activated at elevations higher than 14,000 feet (4,270 meters)
Shutoff:
Automatically shuts off if no dive is made within 120 minutes after initial activation. Reactivation required.
Automatically shuts off 24 hours after last dive (will reactivate if the H2O graphic is displayed).
Cannot be shut off manually.
Setting FO2:
Automatically set for 'Air' upon activation
Remains set for Air unless an FO2 numerical value is set
Nitrox set points from 21 to 50 %
If set for 21%, remains set for 21% until changed
If set for >21%, it reverts to 50% 10 minutes after the dive, if the FO2 Default is ON. If the FO2 Default is OFF, the
value will remain at the value set.
SPECIFICATIONS (CONTINUED)