Operation Manual
93
OPERATIONAL MODES (continued)
No Decompression Dive:
Main 1 (Current Depth, Dive Time Remaining, Bar Graphs)
Main 2 (Current Depth, Dive Time Remaining, Max Depth, Elapsed Dive Time, Bar Graphs)
Main 3 (Current Depth, Dive Time Remaining, Temperature, Time of Day, Bar Graphs)
Main 4 - only if a nitrox dive (Current Depth, Dive Time Remaining, Current PO2, Bar Graphs)
Safety Stop - for dives deeper than 30 feet (9 meters)
Digital Gauge Dive:
Main - default (Current Depth, Elapsed Dive Time, Ascent Rate Indication)
Alternate (Current Depth, Temperature, Time of Day, Ascent Rate Indication)
Decompression Dive:
Main - default (Current Depth, Total Ascent Time, Stop Depth / Time, Bar Graphs)
Alternate 1 (Current Depth, Total Ascent Time, Max Depth, Elapsed Dive Time, Bar Graphs)
Alternate 2 (Current Depth, Total Ascent Time, Temperature, Time of Day, Bar Graphs)
Alternate 3 - only if set for a nitrox dive (Current Depth, Total Ascent Time, Current PO2 value, Bar Graphs)
Violation (Conditional, Delayed, & Immediate/Gauge)
High PO2 (1.20 to 1.60 ATA)
High Oxygen Accumulation (allowed per dive or 24 hour period)
DISPLAY RANGE/RESOLUTION
Numeric Displays: Range: Resolution:
Dive Number 0 to 24 1
Depth 0 to 399 ft (0 to 120 m) 1 ft (.1 m / 1 m > 99.9 m)
Maximum Depth 399 ft (120 m) 1 ft (.1 m / 1 m > 99.9 m)
FO2 Set Point Air, 21 to 50 % 1 %
PO2 Value 0.00 to 5.00 ATA .01 ATA
Dive Time Remaining 0:00 to 9:59 hr:min 1 minute
Total Ascent Time 0:00 to 9:59 hr:min 1 minute
Decompression Stop Time 0:00 to 9:59 hr:min 1 minute
Elapsed Dive Time 0:00 to 9:59 hr:min 1 minute
SPECIFICATIONS (CONTINUED)