Operation Manual
88
Using your fingers, turn the Ring counter clockwise 5 degrees
until the tabs engage (Fig. 94), then tighten it 5 more degrees by
turning it counter clockwise with the aide of a small blade
screwdriver (Fig. 95).
While tightening the Retaining Ring, exert continuous inward
pressure on it until it is secured in the proper position. A small
symbol located on the Ring should be aligned with the Locked
symbol located on the Housing (Fig. 95a).
Inspection
Activate the unit and watch carefully as it performs a full diag-
nostic and battery check, and enters Surface Mode.
Observe the LCD display to ensure it is consistently clear and
sharp in contrast throughout the screen.
WARNING: If any portions of the display are miss-
ing or appear dim, or a Low Battery condition is in-
dicated, return your XR2 to an Authorized AERIS
Dealer for a complete evaluation before attempting
to use it.
Fig. 94 -Engaging Retaining Ring
Fig. 95 -Retaining Ring Tightened
a