Operation Manual
77
When set OFF, it operates as it would as an Air or Nitrox dive
computer.
Press and release the Select (Side) button to toggle between ON
and OFF.
Press and release the Advance (Front) button to accept the set-
ting and advance to DEMO NI-O2 with the graphic NEW (or
CUR) flashing (Fig. 80).
When set for NEW, calculations are based on zero residual ni-
trogen and oxygen loading (a clean dive). When set for CUR,
calculations take into consideration any calculated residual ni-
trogen and oxygen remaining from previous 'actual' dives. Sub-
sequent (repetitive) Simulated dives will not take into consider-
ation data from previous Simulated dives.
Press and release the Select (Side) button to toggle between
NEW and CUR.
Press and release the Advance (Front) button to accept the set-
ting and advance to Demo Surface Mode with the DEMO icon
flashing (Fig. 81).
Press and release the Advance (Front) button to advance to
DEMO FO2 with Air (or a numerical value) flashing (Fig. 82).
Press and release the Select (Side) button to change the FO2 set-
ting from AIR to 21 through 50, in increments of 1%.
Press and release the Advance (Front) button to accept the set-
ting and revert to Demo Surface Mode with DEMO flashing.
Fig. 80 - Demo Set Calibration
Fig. 82 - Demo Set FO2
Fig. 81 - Demo Surface Mode