RESET (CLEAR) FEATURE
The XR2 is configured with a RESET feature that allows data to be
cleared, including Nitrogen and Oxygen calculations, FO2 set
point, and Log Mode entries.
RESET PROCEDURE:
While in Surface Mode (new activation period or after a 10
minute post dive surface interval), press the Advance (Front)
button 1 time to access Plan Mode.
While 30 feet (or 9 meters) is displayed in the Plan Mode, press
and hold Both buttons until SET 2 appears, then release the but-
tons.
Press and release the Advance (Front) button to display the Clear
screen (Fig. 41). The first 2 digits of the KEY CODE flash.
If necessary to change the number, press and release the Select
(Side) button until the digits to change to 01.
Press and release the Advance (Front) button again to save the
first 2 digits and display the second 2 digits of the KEY CODE,
flashing.
If necessary to change the second 2 digits, press and release the
Select (Side) button until the digits change to 01.
Press and release the Advance (Front) button to save the number
displayed, complete the RESET operation, and turn the unit
OFF.
WARNING: Re-
set after a dive
and subsequent
use for a repeti-
tive dive con-
ducted by the
same diver
could result in
serious injury to
or death.
Fig. 41 - Clear (Reset)