TO SET - MAX PO2 ALARM (while in the Surface Mode)
Factory set for 1.60 (ATA), the Max PO2 Alarm can be set to val-
ues between 1.20 and 1.60 (ATA) in increments of .10 (ATA).
Depress Both buttons simultaneously, release when SET 2 ap-
pears (4 seconds).
Press and release the Advance (Front) button, the Units screen
appears with the set point flashing.
Press the Advance (Front) button 10 more times.
The graphic PO2, MAX icon, and Alarm (speaker) icon appear
with the PO2 Alarm value flashing (Fig. 35).
Press and release the Select (Side) button to advance the Alarm
value in increments of .10 (ATA), or press and hold the button
to scroll through the Set Points at a rate of 4 per second.
Press the Advance (Front) button to accept the setting and ad-
vance to Set FO2 50% Default, or depress and hold Both but-
tons for 2 seconds to revert to Surface Mode.
Fig. 35 - Set Max PO2 Alarm