Operation Manual

35
TO SET - DIVE TIME REMAINING (DTR) ALARM
(while in the Surface Mode)
Factory set for 0:00 (minutes), the DTR Alarm can be set to values
between 0:00 and 0:20 (minutes) in increments of 1 minute.
 Depress Both buttons simultaneously, release when SET 2 ap-
pears (4 seconds).
 Press and release the Advance (Front) button, the Units screen
appears with the set point flashing.
 Press the Advance (Front) button 9 more times.
 The graphic dtr, Alarm (speaker) icon, and Dive Mode icon
(wave/clock/profile) appear with the DTR Alarm value flashing
(Fig. 34).
 Press and release the Select (Side) button to advance the Alarm
value in increments of one minute, or press and hold the button
to scroll through the Set Points at a rate of 4 per second.
 Press the Advance (Front) button to accept the setting and ad-
vance to Set Max PO2 Alarm, or depress and hold Both buttons
for 2 seconds to revert to Surface Mode.
Fig. 34 - Set DTR Alarm