Operation Manual
34
TO SET - MAX NITROGEN BAR GRAPH (NiBG) ALARM
(while in the Surface Mode)
Factory set for DECO (all 5 segments), the Max NiBG Alarm can
be set to values between DECO (5 segments) and 1 segment.
Depress Both buttons simultaneously, release when SET 2 ap-
pears (4 seconds).
Press and release the Advance (Front) button, the Units screen
appears with the set point flashing.
Press the Advance (Front) button 8 more times.
The graphic ndc and Alarm (speaker) icon appear with the
NiBG segments flashing (Fig. 33).
Press and release the Select (Side) button to decrease the num-
ber of segments one at a time, or press and hold the button to
scroll through the Set Points at a rate of 4 per second.
Press the Advance (Front) button to accept the setting and ad-
vance to Set Dive Time Remaining Alarm, or depress and hold
Both buttons for 2 seconds to revert to Surface Mode.
Fig. 33 - Set Max NiBG Alarm