Operation Manual
26
Press and release the Advance (Front) button to accept the set-
ting and advance to Set Max Depth Alarm, or depress and hold
Both buttons for 2 seconds to revert to Surface Mode.
The unit reverts to Surface Mode in 2 minutes if no button is
pressed.
TO SET - MAX DEPTH ALARM (while in the Surface Mode)
Factory set for 330 feet, the Maximum Depth Alarm can be set to
values between 30 feet (3 meters) and 330 feet (99 meters) in in-
crements of 10 foot (3 meters).
Depress Both buttons simultaneously, release when SET 1 ap-
pears (2 seconds).
Press and release the Advance (Front) button, FO2 appears with
the set value flashing.
Press and release the Advance (Front) button 1 more time.
The graphic dEEP, MAX and FEET (or M), and Alarm icon
appear with the Max Depth Alarm value flashing (Fig. 22).
Press and release the Select (Side) button until the desired
Alarm value appears, or depress and hold the button to scroll
through the Set Points at a rate of 4 per second.
Press and release the Advance (Front) button to accept the set-
ting and advance to Set Elapsed Dive Time Alarm, or press and
hold Both buttons for 2 seconds to revert to Surface Mode.
The unit reverts to Surface Mode in 2 minutes if no button is
pressed.
Fig. 22 - Set Depth Alarm