Operation Manual
34
Immediate Violation and Violation Gauge Mode
During a Dive, if a Stop Depth greater than 70 FT (21 M) is re-
quired, an Immediate Violation Mode will be entered.
This situation would be preceded by entering Delayed Violation 2,
previously described.
The XR1 would then operate with limited functions in Violation
Gauge Mode during the remainder of that dive and for 24 hours
after surfacing.
Violation Gauge Mode turns the XR1 into a digital instrument
without any decompression functions.
Only Current Depth, Max Depth, Elapsed Dive Time, and the
Variable Ascent Rate Indicator will be displayed (Fig. 33). The
full Nitrogen Bar Graph will flash as a warning of this condition.
Temperature and Time of Day can be viewed as an Alternate Dis-
play (Fig. 37) when the button is pressed.
The XR1 will also enter an Immediate Violation Mode 5 minutes
after reaching the surface from a dive in which a Delayed Viola-
tion occurred.
Fig. 36 - Violation Gauge Mode
(underwater Main)
Fig. 37 - Violation Gauge Mode
(underwater Alternate)
Flashing
Flashing