SET TMT MENU (NORM, GAUG), previously described on page 19.
SET ALARMS MENU (GAUG), information includes (Fig. 64):
Selections with their last Set points saved include:
> AUDIBLE = with ON or OFF.
> DEPTH = with OFF, or 30 to 330 FT (or 10 to 100 M), increments of 10 FT (3 M).
> EDT = with OFF, or 0:10 to 3:00 (hr:min), increments of :05. EDT is Elapsed Dive Time.
> TURN = with OFF, or 1000 to 3000 PSI (or 70 to 205 BAR), increments of 250 PSI (5 BAR). TURN is pressure of TMT 1.
> END = with 300 to 1500 PSI (or 20 to 105 BAR), increments of 100 PSI (5 BAR). END is pressure of the TMT in use.
A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
M (< 2 sec) - to step back (up screen) through Menu selections.
S (< 2 sec), when a selection is highlighted - to highlight & flash that item’s set point.
A (< 2 sec) - to toggle or increase the set point.
A (hold) - to increase the set point at a rate of 8 per second.
M (< 2 sec) - to toggle or decrease the set point.
S (< 2 sec) - to save the setting and revert to the Set Alarms Menu.
SET UTILITIES MENU (GAUG), information includes (Fig. 65):
Selections with their last Set points saved include:
> WATER = with FRESH or SEA.
Depth values will be based on the type of water
.
> UNITS = with IMPERIAL or METRIC.
> SAMPLING = with 2, 15, 30, or 60 SEC (second).
Rate that data is sampled and recorded for PC download
.
Additional information relating to the effects of the items included are described in associated sections throughout this manual.
A (< 2 sec) - to step forward (down screen) through and highlight Menu selections.
M (< 2 sec) - to step back (up screen) through Menu selections.
S (< 2 sec), when a selection is highlighted - to highlight & flash that item’s set point.
A (< 2 sec) - to toggle or increase the set point.
A (hold) - to increase the set point at a rate of 8 per second.
M (< 2 sec) - to toggle or decrease the set point.
S (< 2 sec) - to save the setting and revert to the Set Utilities Menu.
GAUG DIVE PREVIEW, information includes (Fig. 66):
Upon accessing this screen from the GAUG MENU, the items illustrated will be displayed with the settings last saved.
Turn and End Alarms will not be displayed unless a TMT is in use.
S or M (2 sec) to step back to the GAUG MENU with VIEW PREVIEW highlighted.
Fig. 64 - SET ALARMS
Fig. 65 - SET UTILITIES
Fig. 66 - VIEW PREVIEW
GAUG SET ALARMS
AU DI B LE =
EDT =
TUR N =
END =
DEP T H =
ON
150 FT
0:4 0
150 0 P S I
300 PS I
GAUG SET UTILITIES
WAT ER =
SAM P LI N G =
UNI TS =
15 S E C
FRE S H
MET R IC
DEP T H A L =
EDT A L =
TUR N A L =
END AL =
WAT ER =
GAUG DIVE PREVIEW
150 FT
0:4 0
150 0 P S I
300 PS I
FRE S H