A300 CS OPERATING MANUAL A300 CS DIVE COMPUTER OPERATING MANUAL © 2002 Design, 2014 1 Doc. No.
A300 CS OPERATING MANUAL Welcome to AERIS and Thank You for choosing the A300 CS © 2002 Design, 2014 2 Doc. No.
A300 CS OPERATING MANUAL Contents NOTICES................................................................................................4 GAS/TMT SWITCHING........................................................................32 OVERVIEW......................................................................................33 NORM GAS SWITCH MENU...........................................................33 GAUG TMT SWITCH MENU...........................................................
A300 CS OPERATING MANUAL NOTICES LIMITED TWO-YEAR WARRANTY For details, refer to the Product Warranty Registration Card provided. Register on line at www.diveaeris.com COPYRIGHT NOTICE This operating manual is copyrighted, all rights are reserved. It may not, in whole or in part, be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine readable form without prior consent in writing from AERIS/2002 Design. A300 CS Operating Manual, Doc. No.
A300 CS OPERATING MANUAL ACTIVATION and OVERVIEW © 2002 Design, 2014 5 Doc. No.
A300 CS OPERATING MANUAL INTERACTIVE CONTROL CONSOLE The interactive control console utilizes 3 control buttons that are referred to as M, A, and S (Fig. 1). • M (left front) - Menu, Mode, Minus (decrease) • A (right front) - Advance, Add (increase). • S (right side) - Select, Save. Activation To activate the A300 CS, press/release any button. • A Welcome screen will be displayed for 3 seconds (Fig.
A300 CS OPERATING MANUAL SAMPLE DISPLAY LAYOUTS SURFACE MAIN BATT SURF SET MENU 2:48 NORM GAS 1 TL 850 PSI DIVE 3 DIVE MAIN 86 FT NDC 0:24 NORM SET ALARMS BATT AUDIBLE DEPTH EDT TLBG DTR TURN END DS = ON = 130 FT = 0:40 = 8 SEG = 0:10 = 1500 PSI = 300 PSI GAS 1 TL AR ATR 1480 PSI 42 DISPLAY ICONS & GRAPHIC ABBREVIATIONS (Full character graphics, such as AUDIBLE, are not listed below.
A300 CS OPERATING MANUAL POWER SUPPLY • A300 CS Battery >> (1) 3 vdc, CR2, Lithium, 800 mAh - Duracell, Energizer, Panasonic, or RayOvac recommended. • Use life (examples) >> 15 hours at 100% Brightness with Auto Dim set off; 34 hours at 60% Brightness with Auto Dim To time set for 10 seconds and Dim level set for 10%. Refer to page 62 for more information relating to power usage.
A300 CS OPERATING MANUAL BRIGHTNESS CONTROL The level (%) of screen Brightness can be adjusted by accessing the Brightness Adjustment screen while viewing the Home Menu screen, or a Surface or Dive Main screen (NORM, GAUG, or FREE), or the Compass OP Main screen. • A (2 sec), while on the surface or during dives, will access a Brightness adjustment screen with the last % highlighted and flashing. During a Low Battery Warning or Alarm condition, the level will be limited to 60% maximum.
A300 CS OPERATING MANUAL OPERATING MODES HOME >> This is a base mode that provides access to general items common to the operating dive modes. NORM >> This is an operating dive mode used for Air and Nitrox scuba activity with up to 4 gases and transmitters. If no previous dive has been taken within the past 24 hours, NORM is the default mode upon activation with others accessed as described later.
A300 CS OPERATING MANUAL HOME MODE © 2002 Design, 2014 11 Doc. No.
A300 CS OPERATING MANUAL HOME MENU The Home Menu is displayed after activation and diagnostics. When the NORM, GAUG, FREE, or Compass Surface Main screen is displayed, the Home Menu can be accessed by pressing M for 2 seconds. • At any time while operating in the Home Menu system, pressing M (2 sec) will revert to the Home Menu screen. • Operation will also revert to the Home Menu screen if no button is pressed within a 2 minute period. Selections include (Fig.
A300 CS OPERATING MANUAL HOME SETUP MENU, selections include (Fig. 15): > SET AUTO DIM - select to access the Set Auto Dim feature. > SET DATE, TIME - select to access the Set Date, Time Menu. > BATT, TMT STATUS - select to activate the A300 CS' receiver then view status information for the A300 CS and Transmitters. > BLUETOOTH - select to initialize the Bluetooth function. • • • • A (< 2 sec) - to step forward (down) through the Menu selections. M (< 2 sec) - to step back (up) through the selections.
A300 CS OPERATING MANUAL BLUETOOTH The A300 CS contains a Bluetooth module that can be paired with a PC, Mac, or mobile device. Bluetooth is initialized while the selection is highlighted on the Home Setup Menu (by S < 2 sec). A Please Wait screen (Fig. 19A) will be displayed for 5 seconds followed by a screen displaying a countdown from 120 to 0 seconds (Fig. 19B). PC DC P L E A S E WA I T. . . Fig.
A300 CS OPERATING MANUAL LOG MODE (NORM/GAUG) Information from the latest 24 NORM and/or GAUG dives is stored for viewing. After exceeding 24 dives, the most recent dive is stored while the oldest is deleted. > Dives are numbered from 1 to 24 starting each time NORM (or GAUG) mode is activated. After 24 hours elapse with no dive, the first dive of the next period of operation is #1. > 10 minutes after a dive, the Log screens for all dives stored can be viewed.
A300 CS OPERATING MANUAL NORM SURFACE MODE © 2002 Design, 2014 16 Doc. No.
A300 CS OPERATING MANUAL NORM SURFACE MODE Upon access to NORM mode, the Surface Main screen will be displayed during which time the unit will enter Dive Mode upon descent to 5 FT (1.5 M) for 5 seconds. If 2 minutes elapse with no button action, operation will enter Power Saver Mode turning the screen off until a button is pressed. The unit will enter Post Dive Surface Mode upon ascent to 2 FT (0.6 M) for 1 second and display the Surface Main with the SURF icon flashing.
A300 CS OPERATING MANUAL NORM MENU, information includes (Fig. 26): > PLAN - to view a sequence of allowed depths with no deco times. > SET GAS - to access a menu for setting FO2 and PO2 alarms for each gas. > SET TMTS - to access a menu for setting transmitters. > SET ALARMS - to access a menu for setting dive alarms. > SET UTILITIES - to access a menu for setting dive related functions such as algorithm, stops, etc.
A300 CS OPERATING MANUAL > Internally, the unit will keep track of the oxygen accumulation so that if FO2 for Gas 1 is subsequently set for Nitrox, the oxygen accumulated during previous AIR dives will be accounted for in the next Nitrox dive (during that dive period and series of repetitive dives). FO2 set for Nitrox: > When FO2 for any Gas is set for Nitrox (21 to 100%), the dive is calculated to be for Nitrox.
A300 CS OPERATING MANUAL SET ALARMS MENU (NORM), information includes (Fig. 30): NORM SET ALARMS Selections with their last Set points saved include: > AUDIBLE = with ON or OFF. > DEPTH = with OFF, or 30 to 330 FT (or 10 to 100 M), increments of 10 FT (3 M). > EDT = with OFF, or 0:10 to 3:00 (hr:min), increments of :05. EDT is Elapsed Dive Time. > TLBG = with 1 to 8 SEG, increments of 1 SEG. SEG means Segments of the bar graph > DTR = with OFF, or 1 to 0:20 ( :min), increments of :01.
A300 CS OPERATING MANUAL NORM DIVE PREVIEW, information includes (Fig. 33): Upon accessing this screen from the NORM MENU, the items selected using the NORM Set Preview function previously described will be displayed with the settings last saved. The illustration shown is a sampling of various items selected with their settings. • S or M (2 sec) to step back to the NORM MENU with VIEW PREVIEW highlighted.
A300 CS OPERATING MANUAL DIVE MODE FEATURES © 2002 Design, 2014 22 Doc. No.
A300 CS OPERATING MANUAL Transmitter Signal Reception Guide Poor Reception Area Best Reception Area Poor Reception Area Poor Reception Area Poor Reception Area Poor Reception Distance (greater than 3 feet/1.0 meters) PROXIMITY OF THE TMTS (Transmitters) AND A300 CS The TMTs emit low frequency signals that radiate out in semicircular patterns parallel to the length dimension of the TMT.
A300 CS OPERATING MANUAL WET ACTIVATION The A300 CS is configured with contacts that will automatically activate Dive Mode when the space between the contacts is bridged by a conductive material (immersed in water) and it senses a Depth of 5 FT (1.5 M). The contacts are the metal pins of the PC/Mac Interface Data Port and the stems of the buttons. bar graphS The A300 CS features 2 bar graphs, one on each side of the LCD (Fig. 35). > The one on the left represents nitrogen loading.
A300 CS OPERATING MANUAL SAFETY STOP (SS) If set ON: Upon ascent to within 5 FT (1.5 M) deeper than the SS Depth set for 1 second on a No Deco dive in which Depth exceeded 30 FT (9 M) for 1 second, a beep will sound and a SS at the Depth set will appear on the Main display with a countdown beginning at the SS Time set and counting down to 0:00 (min:sec). • If the SS was set for OFF or TIMER, this display will not appear.
A300 CS OPERATING MANUAL NORM DIVE MODE © 2002 Design, 2014 26 Doc. No.
A300 CS OPERATING MANUAL NO > > > > > DECO MAIN, information includes** (Fig. 40A/B): BATT icon - green (if battery voltage is good), or yellow (if at warning level), or red (if at alarm level). Current Depth with FT (or M) icon. Dive Time Remaining (hr:min) with NDC (or OTR) icon. Graphic GAS 1 (or 2, 3, 4), one in use. Pressure with PSI (or BAR) icon, if the Receiver and Transmitter are active, flashing when Link is lost; or graphic SPG when no Transmitter is in use (SPG = Submersible Pressure Gauge).
A300 CS OPERATING MANUAL SAFETY STOP (SS) MAIN, information includes (Fig. 45A/B): > BATT icon - green (if battery voltage is good), or yellow (if at warning level), or red (if at alarm level). > Current Depth with FT (or M) icon. > Graphic SAFETY STOP with Stop icon (arrows and bar). > Stop Depth with FT (or M) icon & countdown Time (min:sec); or graphic RT with Run Time counting up from 0:00 to 9:59 (min:sec). > Graphic GAS 1 (or 2, 3, 4), one in use.
A300 CS OPERATING MANUAL CONDITIONAL VIOLATION (CV) Upon ascent above the required Deco Stop Depth, operation will enter CV during which no off gassing credit will be given, meaning Deco Stop Time and TAT will not decrease. A penalty time of 1 1/2 minutes will be added for each minute above the required Stop Depth. BATT 14 FT DOW N TO S TO P The Audible will sound for 10 seconds during which the full TLBG will flash.
A300 CS OPERATING MANUAL VIOLATION GAUGE MODE (VGM) If a Deco Stop Depth greater than 70 FT (21 M) is required, operation will enter VGM. This would be preceded by DV2. Operation would then continue in VGM during the remainder of that dive and for 24 hours after surfacing. VGM turns the A300 CS into a digital instrument without any decompression or oxygen related calculations or displays. Upon activation of VGM, the Audible will sound for 10 seconds during which full TLBG* will flash, then be removed.
A300 CS OPERATING MANUAL High O2 Warning >> at 80 to 99% (240+ OTU). Alarm >> at 100% (300+ OTU). BATT O2SAT = 80% When O2 reaches the Warning level; the Audible will sound during which the graphics O2SAT = 80% (yellow) will flash in place of DTR (Fig. 57A). After the audible is silenced, DTR will be restored. AR GAS 1 TL If O2 reaches the Alarm level; the Audible will sound again during which the graphics GO UP O2 = 100% with Up Arrows (red) will flash (Fig. 57B).
A300 CS OPERATING MANUAL GAS/TMT SWITCHING © 2002 Design, 2014 32 Doc. No.
A300 CS OPERATING MANUAL OVERVIEW > Can only switch when a Dive Main screen is displayed. > Cannot Switch Gas or TMTs on surface, except during the first 10 minutes after surfacing from a dive. > Cannot Switch Gas or TMTs during sounding of alarms. > All NORM dives begin with Gas 1 and default to Gas 1 after 10 minutes on the surface. > Switching Gas also switches TMTs, if being used. The following will describe NORM GAS/TMT Switching, then GAUG TMT Switching.
A300 CS OPERATING MANUAL GAUG OP MODE © 2002 Design, 2014 34 Doc. No.
A300 CS OPERATING MANUAL GAUG SURFACE MODE The Surface Main screen will remain on display for 10 minutes during which time the unit will enter Dive Mode upon descent to 5 FT (1.5 M) for 5 seconds. If 10 minutes elapses with no button action, operation will enter Power Saver Mode (PSM). Operation will enter Post Dive Surface Mode upon ascent to 2 FT (0.6 M) for 1 second and display the Surface Main with the SURF icon flashing.
A300 CS OPERATING MANUAL SET TMT MENU (NORM, GAUG), previously described on page 19. SET ALARMS MENU (GAUG), information includes (Fig. 64): GAUG SET ALARMS Selections with their last Set points saved include: > AUDIBLE = with ON or OFF. > DEPTH = with OFF, or 30 to 330 FT (or 10 to 100 M), increments of 10 FT (3 M). > EDT = with OFF, or 0:10 to 3:00 (hr:min), increments of :05. EDT is Elapsed Dive Time. > TURN = with OFF, or 1000 to 3000 PSI (or 70 to 205 BAR), increments of 250 PSI (5 BAR).
A300 CS OPERATING MANUAL GAUG DIVE MAIN, information includes (Fig. 67A/B): Either Elapsed Dive Time (EDT) or a Run Time can displayed on the Main screen with the other on the ALT (Alternate) screen. > BATT icon - green (if battery voltage is good), or yellow (if at warning level), or red (if at alarm level). > Current Depth with FT (or M) icon.
A300 CS OPERATING MANUAL FREE DIVE OP MODE © 2002 Design, 2014 38 Doc. No.
A300 CS OPERATING MANUAL FREE SURFACE MODE FREE dives, which are allowed prior to NORM or GAUG dives as well as after NORM dives, calculate Ni-O2 based upon the Algorithm selected and a fixed default FO2 of Air. FO2 settings for NORM dives do not affect calculations for FREE Dives. FREE mode displays NDC Time (on a dive ALT screen) and the TLBG (TL) on surface and dive Main screens, and includes a TLBG Alarm that activates when it enters the yellow Caution zone (9 segments).
A300 CS OPERATING MANUAL FREE MENU, information includes (Fig. 76): > CDT SETUP - to access a screen to set a Countdown Time, then select On/Off. > SET MENU - to access a menu for setting dive related functions. • • • • A or M (< 2 sec) - to toggle between Menu selections (the active item highlighted). S (< 2 sec) - to access the selection that is highlighted. M or S (2 sec) - to step back from the Menu to the FREE SURF MAIN.
A300 CS OPERATING MANUAL FREE DIVE MAIN, information includes (Fig. 80A/B) - BATT Either Elapsed Dive Time (EDT) or the Countdown Timer (CDT) can displayed on the Main screen with the other on the Alternate. Due to short dive times, the Auto Dim feature that automatically dims the screen to a lower level of brightness is not active during FREE dives. Brightness will remain at the % you adjust it to until you change it.
A300 CS OPERATING MANUAL ADDITIONAL INFORMATION PERTAINING TO FREE DIVE MODE Although breathing apparatus is not utilized for FREE Dive activities, nitrogen tissue loading remains a factor. calculated based upon a fixed FO2 of AIR.
A300 CS OPERATING MANUAL COMPASS MODE © 2002 Design, 2014 43 Doc. No.
A300 CS OPERATING MANUAL COMPONENTS NORTH MODE REFERENCE MODE Diver’s Direction of Travel Diver’s Direction of Travel Heading Set Turn Right Turn Left N Diver's actual Heading W N Diver's actual Heading 000 ° E 15 SEC North OP Mode 000° W SEC 000 OP Mode Reference Reverse Compass Time remaining when <= 15 sec. E 15 Compass Time remaining when <= 15 sec. Heading Set COMPASS MODE SURFACE Home Menu Surface Main S < 2s S 2s (2 min) COMP OP.
A300 CS OPERATING MANUAL OVERVIEW > S (2 sec) - to access Compass OP (operating) Main from Surface or Dive Main. > S (2 sec), or no button action (2 min*) - to revert to Surface or Dive Main. *During the final 15 seconds, the remaining On time is displayed. If a button is pressed during that time, the 2 minute On time will reset allowing operation to remain in Compass Mode. > > > > Compass OP (operating) Mode selected (North or Reference) - remains until changed.
A300 CS OPERATING MANUAL REFERENCE MENU, information includes (Fig. 87A) > Current Depth with FT (or M) icon, blank on surface. > SET HEADING. > REVERSE HEADING. > Reference Mode icon (2 bars with arrow) with numeric heading set below it. > On time remaining, counting down, if 15 to 0 (sec). 35 FT SET HEADING REVERSE HEADING 11 SEC 260 Fig. 87A - REFERENCE MENU • A or M (< 2 sec) - to toggle between SET and REVERSE.
A300 CS OPERATING MANUAL Calibration complete > Once fully formed, the circle will be replaced with the graphics READY PASSED CALIBRATION (Fig. 88E) or FAILED CALIBRATE AGAIN (Fig. 88F), flashing for 3 seconds, then > If READY, operation reverts to the Compass OP Main. > If FAILED, operation reverts to the TURN FACE DOWN screen for repeat of the procedure. > If Calibration fails 3 times, operation reverts to the Surface Main screen.
A300 CS OPERATING MANUAL NORM/GAUG DIVE MODE ALARMS © 2002 Design, 2014 48 Doc. No.
A300 CS OPERATING MANUAL 140 FT 0:24 BATT DEPTH ALARM (Fig. A1) NDC Audible >> sounds until acknowledged, time out (10 sec), or ascent is made to a depth less than the value set. DS GAS 1 Depth digits >> flash (red) during Audible, then solid (white). 980 PSI TL ATR 9 Fig. A1 - DEPTH ALARM ELAPSED DIVE TIME (EDT) ALARM (Fig. A2) 36 FT 1:00 BATT Audible >> sounds until acknowledged or time out (10 sec).
A300 CS OPERATING MANUAL AIR TIME REMAINING (ATR) ALARM (at 0 min) (Fig. A9) BATT Audible >> sounds until acknowledged or time out (10 sec), or ATR => 1 min. NDC ATR digits & icon >> flash (red) until the Audible is silenced, then the digits flash (yellow) until ATR > 5 min, then return to solid (normal color, green). 27 FT 0:23 GAS 1 TL 360 PSI AR ATR 0 Fig. A9 - ATR WARNING LOST LINK WITH TRANSMITTER (TMT in use) (Fig. A10) Activate >> TMT signal interrupted for 15 sec.
A300 CS OPERATING MANUAL REFERENCE CAUTION: When the procedure provided in this section is used to change the A300 CS Battery, you must be sure that the case o-ring is not pinched and that the A300 CS is water tight before conducting diving actvities. Pre dive pressure testing by an Authorized AERIS facility is highly recommended. © 2002 Design, 2014 51 Doc. No.
A300 CS OPERATING MANUAL UPLOADING/DOWNLOADING As previously described (page 13), the A300 CS can be paired with a PC, Mac, or mobile device utilizing the Bluetooth function together with a dongle (Fig. 91) that plugs into the PC/Mac USB port. The dongle can be obtained as an optional accessory. It can also be connected with a PC or Mac using a USB cable and adapter clip provided. USB Connection The A300 CS is configured with a 4 pad interface connection port located on the back of the case (Fig. 92).
A300 CS OPERATING MANUAL ALTITUDE SENSING AND ADJUSTMENT Prior to the first dive of a series of repetitive dives, Altitude (i.e., ambient pressure) is measured upon activation then every 15 minutes until a dive is made. > Measurements are only taken when the unit is dry. > Two readings are taken, the second reading 5 seconds after the first. The readings must be within 1 foot (30 cm) of each other to record that ambient pressure as the current Altitude.
A300 CS OPERATING MANUAL battery replacement The procedures that follow must be closely adhered to to avoid entrance of water into the unit. Damage due to improper Battery replacement (or subsequent leakage of moisture into the unit) is not covered by the A300 CS's 2 year warranty. The Battery Compartment should only be opened in a dry and clean environment with extreme care taken to prevent the entrance of moisture or dust.
A300 CS OPERATING MANUAL Transmitter Battery RePLACEMENT Battery Removal Locate the Battery Cover on the end of the housing: • Apply a coin to the recessed slot of the Cover and turn it counter clockwise out of the housing (Fig. 101). • Remove the Battery and discard it according to local regulations governing disposal of Lithium batteries. Fig. 101 - COVER REMOVAL Battery Installation • Lightly lubricate the new Battery Cover O-ring with silicone grease and install it onto the Battery Cover.
A300 CS OPERATING MANUAL TECHNICAL DATA © 2002 Design, 2014 56 Doc. No.
A300 CS OPERATING MANUAL SPECIFICATIONS CAN BE USED AS • Dive Computer (Air or Nitrox) with up to 4 Gases up to 100% O2 and 4 Transmitters. • Digital Depth Gauge/Timer with up to 4 Transmitters. • Free Dive (breath hold) activity with Depth Gauge, Countdown Timer. • Compass. DIVE COMPUTER PERFORMANCE • Buhlmann ZHL-16c based Pelagic Z+, or DSAT based, algorithm. • No Deco limits closely follow PADI RDP. • Decompression in agreement with Buhlmann ZHL-16c and French MN90.
A300 CS OPERATING MANUAL SPECIFICATIONS (CONTINUED) Battery Indication: • Good (> 2.75 v) >> BATT Icon (green) solid on Surface and Dive Mains. No restrictions surface or dive.. • Warning (<= 2.75 v) >> BATT Icon (yellow) solid on Surface and Dive Mains, Battery change recommended. Brightness level automatically limited to 60% maximum. • Alarm (<= 2.50 v) >> BATT Icon (red) flashing on Surface and Dive Mains.
A300 CS OPERATING MANUAL SPECIFICATIONS (CONTINUED) NUMERIC DISPLAYS: Range: Resolution: • FREE Surface Interval • FREE Dive Number 0:00 to 59:59 min:sec 1:00 to 23:59 hr:min 0 to 99 1 second 1 minute 1 • FREE Countdown Timer • FREE Elapsed Dive Time 9:59 to 0:00 min:sec 0:00 to 9:59 min:sec 1 second 1 second • Compass Heading • Compass Op Time Remaining 001 to 360° 15 to 1 sec 001° 1 sec WARNING: If your A300 CS stops working for any reason while operating as a Dive Computer, it is importan
A300 CS OPERATING MANUAL DSAT based NDLs (hr:min) (Imperial) Altitude (feet) Depth (FT) 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 0 to 3000 3001 to 4000 4001 to 5000 5001 to 6000 6001 to 7000 7001 to 8000 8001 to 9000 9001 to 10000 10001 to 11000 11001 to 12000 12001 to 13000 13001 to 14000 4:20 2:17 1:21 0:57 0:40 0:30 0:24 0:19 0:16 0:13 0:11 0:09 0:08 0:07 0:07 0:06 0:05 3:21 1:43 1:03 0:43 0:31 0:24 0:19 0:15 0:12 0:09 0:07 0:07 0:06 0
A300 CS OPERATING MANUAL Z+ based NDLs (hr:min) (Imperial) Altitude (feet) Depth (FT) 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 0 to 3000 3001 to 4000 4001 to 5000 5001 to 6000 6001 to 7000 7001 to 8000 8001 to 9000 9001 to 10000 10001 to 11000 11001 to 12000 12001 to 13000 13001 to 14000 3:17 1:49 1:05 0:48 0:35 0:26 0:19 0:16 0:12 0:10 0:08 0:07 0:06 0:06 0:05 0:05 0:04 2:30 1:21 0:53 0:37 0:26 0:19 0:15 0:11 0:09 0:08 0:07 0:06 0:05 0:0
A300 CS OPERATING MANUAL ADDITIONAL INFORMATION PERTAINING TO BRIGHTNESS & POWER CONSUMPTION As indicated in various sections of this manual, there are numerous factors that affect battery consumption. Some can reduce battery use life quite rapidly such as keeping the Brightness level set at 100% and not taking advantage of the Auto Dim feature to conserve power when the screen is not being viewed during dives.
A300 CS OPERATING MANUAL INSPECTION / SERVICE Record A300 CS Serial Number: ___________________________________________________________________________________________________ A300 CS Firmware Rev: ___________________________________________________________________________________________________ Transmitter1 Serial Number: ___________________________________________________________________________________________________ Transmitter 2 Serial Number: _________________________________________________
A300 CS OPERATING MANUAL A300 CS DIVE COMPUTER OPERATING MANUAL © 2002 Design, 2014 64 Doc. No.