Manual
800-543-9038 USA 866-805-7089 CANADA 203-791-8396 LATIN AMERICA
7
F6…HD Butter
fl
y Valves 2”–30” Ductile Iron Lu
g
Body
Resilient Seat, 304 Stainless Dis
c
Maximum Dimensi
o
ns (Inches
)
Valve Size C
v
90° C
v
60° A B C D(Max) BHC No. of Holes Lug Bolt Actuator Close-Off (PSI)
2”
115
44
1
.
65
9
.
00
9
.
00
19
.
50
4
.7
5
4
5
/
8-11UN
C
AF
200
Fail
S
af
e
F665
HD 2½”
196
7
5
1.7
6
9
.
00
9
.
00
20
.
00
5
.
50
4
5
/
8-11UNC
2
*AF
200
F
680HD
3
”
3
02
1
16 1.78
9
.00
9
.00
2
0.50
6
.00
4
5/8-11UN
C
2
00
F
650HD
2
”
1
15
44
1.65 7.00
7
.00
1
5.00
4
.75
4
5/8-11UNC
A
MB
(
X
)
2
00
Non-Fail
S
afe
F
665HD 2½”
1
96 75 1.76 7.00
7
.00
1
5.50 5.50
4
5/8-11UNC
2
00
F
680HD
3
”
3
02
1
16 1.78 8.00 8.00
1
6.00
6
.00
4
5
/
8-11UNC
G
MB
(
X
)
2
00
F6
1
00
HD 4”
600
230
2.
05
8
.
00
8
.
00
2
1.
00
7
.
50
8
5/8-11UNC
2
*
G
MB
(
X
)
200
Valve Size C
v
90° C
v
60° A(Max) B (Max) C (Max) D(Max) BHC No. of Holes Lug Bolt Actuator Close-Off (PSI)
2”
11
5
44
1
.
6
5
8
.
00
13
.
00
20
.
2
5
4
.75
4
5/8-11UN
C
S
Y2…
200
Non-Fail
S
af
e
F
665HD 2½”
1
96 75 1.76 8.00 13.00
2
0.75 5.50
4
5
/
8-11UN
C
200
F
680HD
3
”
3
02
1
16 1.78 8.00 13.00
2
1.00
6
.00
4
5/8-11UNC 200
F6
1
00
HD 4”
600
230
2.
05
8
.
00
1
3
.
00
2
1.7
5
7
.
50
8
5
/
8-11UNC 2
00
F
6125HD 5” 1022
3
92 2.14 8.00 13.00
2
2.25
8
.50 8
3
/4-10UNC 200
F6
1
50
HD
6
”1
5
7
9
605
2.1
9
8
.
00
1
3
.
00
2
2.7
5
9
.
50
8
3
/4-10UNC
S
Y3…
2
00
F6200HD
8”
3136
1202
2
.
3
7
12
.
00
1
5.
00
29
.
00
11
.75
8
3
/4-10UN
C
S
Y4…
200
F
6250HD 10” 5340 2047 2.58 12.00 15.00
3
0.00
1
4.25 12
7
/8-9UNC 200
F6300HD
12”
82
5
0
3062
3
.
01
12
.
00
1
5.
00
32
.
00
1
7.
00
12
7
/8-9UN
C
200
F63
5
0HD
14”
1191
7
4
5
68
3
.
02
12
.
00
1
5.
00
33
.
00
18
.75
12
1-8UN
C
S
Y5…
1
5
0
F6
4
00
HD 1
6
”
16388
6
2
8
2
3
.
39
12.
00
1
5
.
00
3
4.
50
2
1.2
5
1
6
1-8
U
N
C
SY6…
†
1
50
F64
5
0HD
18”
21
7
0
5
8320
4
.
13
14
.
00
21
.
00
39
.
2
5
22
.75
16
1 1/8-7UN
C
S
Y8…
†
1
5
0
F
6500HD 20” 27908
1
0698 5.00 14.00
2
1.00
4
1.50
2
5.00
20
1 1/8-7UN
C
150
F6600HD
24”
43116
16
5
28
5.
94
14
.
00
22
.
00
5
3
.
2
5
29
.5
0
20
1 1
/
4-7UNC
S
Y11…
†
1
5
0
F6
7
50
HD
30
” 7
3
42
6
2
8
14
6
6
.
5
7 14.
00
2
2.
00
5
7.
50
36
.
00
28
1 1
/
4-7UN
C
S
Y12…
†
1
50
D
imension “A” is com
p
ressed, add .125” for relaxed state.
†
SY6 and larger available in 110/220 VAC versions onl
y.
AF, AM and GM maximum actuator ambient temperature is 122°F.
S
Y... maximum actuator ambient temperature is 150°F.
App
lication Notes
1. Valves are rated at 200
p
si differential
p
ressure in the closed
p
ositio
n
(
SY... 150 psi 14”+
)
.
2. Valves are furnished with lu
g
s tapped for use with ANSI Class 125/150
fl anges. Installation fl anges and hardware are not included
.
3. 2-way assemblies are furnished assembled and tested, ready for installation
.
4
. Dimen
s
ion “D” allow
s
for actuator removal without the need to remove the
valve from the
p
i
p
e.
5. Weather shields are available, dimensional data u
p
on request
.
6. Dual actuated valve
s
have actuator
s
mounted on a common valve
s
haft
.
7. Belimo
S
Y
S
eries actuators are NEMA 4X rated.
Dimensions
BF2W
U
DIM
Flow Pattern
0
10
20
10
30
50
40
60
80
70
90
20
30
40
60
5
0
7
0
80
100
90
100
%
O
F MAXIM
U
M FL
O
W
%
O
F VALVE
O
PENIN
G
D
A
B
C
0