Specifications

AerAtron >> Silent Efficiency
IFTHEREAREANYPROBLEMSDURINGINSTALLATIONOFTHEFAN,THEINSTALLERMUSTCONTACTTHEAERATRON
HELPLINEBEFORELEAVINGTHESITE:SWISSPRECISION+61410465228
Installation - Operation – Maintenance - Warranty
4
Ensureceilingjoistsaresoundandofadequatesizeandstrengthtosupporta35Kg(77lb)load.
Toreducetheriskoffire,electricalshockorpersonalinjury,ensurethatthefanmounting
bracketissupporteddirectlyfromthebuildingstructure.DONOTmounttoanoutletbox.
Themountingbracketmustbefirmlyscrewedtoaloadbearingstructuree.g.aconcreteceiling,steel
structureor
timberframe.Ifatimberframeistobeaddeditmustbesecurelynailedorscrewed
betweentwobeams.
Mechanicalissues
Donotremovethefanfromtheceilingafterinstallation.
DonotattachtheFanAssemblybeforetheFanMotorHousingisinstalledandsecured.Toprotectthe
finish,theFanMotorHousingshouldbekeptinthecartonuntilreadytobeinstalled.
Afterthefaniscompletelyinstalled,
checktomakesurethatallconnectionsaresecuretopreventthe
fanfromfallingand/orcausingdamageorinjury.
Toreducetheriskofpersonalinjury,donotbendordamagethemotorDriveShaftorFanAssembly
whenhandlingorinstalling
Aeratronfansareequippedwithaself‐
balancingsystemanddonotrequiremanualbalancing!
Electricalissues
!Meansfordisconnectionmustbeincorporatedinthefixedwiringinaccordancewithnationalwiring
rules!
Thefancanbeusedinconjunctionwithsomehomeautomationsystems.Forfurtherinformation
pleasecontactAeratronPtyLtd.
Toavoidpossibleelectricshockduringinstallation,besureelectricityisturnedoff
atthemainpower
boxbeforecommencingwork.Disconnectpowerbyremovingfuseorturningoffcircuitbreaker
beforeinstallingthefan.Ensureallsplicedconnectionsareadequatelyinsulated.
Note:
Nothinginthismanualisintendedtoins tructorassistuntrainedorunqualifiedpersonstoinstallthis
product.Additionally,itistheresponsibilityoftheinstallerandusertoapplycommonsenseandcare
atalltimes.