AerAtron Ceiling fans User Manual & Technical Specifications Models: e502 & e503 Electricians PLEASE FOLLOW THESES INSTRUCTIONS CAREFULLY & PAY SPECIAL ATTENTION TO THE “NOTES” NOTES WILL ASSIST WITH AN EFFICIENT, PROPER INSTALLATION Australian edition 2013
AerAtron >> Silent Efficiency Instructions ................................................................................................................................................................ 3 General precautions .............................................................................................................................................. 3 Location and installation requirements for your fan.........................................................................................
AerAtron >> Silent Efficiency Instructions Thank you for choosing an Aeratron™ Ceiling Fan. You have chosen the best! We are confident that your new ceiling fan will provide many years of enjoyment. General precautions Please read and follow these instructions carefully, and be mindful of all warnings shown throughout this manual. This fan must be installed by a licensed and qualified electrician according to local authority regulations.
AerAtron >> Silent Efficiency Ensure ceiling joists are sound and of adequate size and strength to support a 35Kg (77lb) load. To reduce the risk of fire, electrical shock or personal injury, ensure that the fan mounting bracket is supported directly from the building structure. DO NOT mount to an outlet box. The mounting bracket must be firmly screwed to a load bearing structure e.g. a concrete ceiling, steel structure or timber frame.
AerAtron >> Silent Efficiency Unpacking your fan Unpack your fan and check the contents. Do not discard the carton. If warranty replacement or repair is ever necessary, the fan should be returned in the original packaging. Examine all parts.
AerAtron >> Silent Efficiency Checking ceiling condition and preparing for fan installation Before commencing installation, turn off electricity supply at the main power box. Disconnect power by removing fuse or turning off circuit breaker before commencing work. Installation mounted to Ceiling Joist Install mounting bracket to ceiling joist using the screws and washer provided. The mounting plate should be able to hold a weight of at least 18kgs.
AerAtron >> Silent Efficiency Installing Remote Control Receiver into hanger bracket Note: Installing more than 1 Fan! Power up each Receiver and code match before installation (see page 9) Slide Remote Control Receiver into Hanger Brackets in orientation shown After installing receiver, re‐ adjust Fan Motor assembly to ensure the drive shaft is vertical IF THERE ARE ANY PROBLEMS DURING INSTALLATION OF THE FAN, THE INSTALLER MUST CONTACT THE AERATRON HELP LINE BEFORE LEAVING THE SITE: SWISS PRECISION +
AerAtron >> Silent Efficiency Make LIVE, GROUND and NEUTRAL connections from Mains Power (House) to Terminal Block. Make LIVE, GROUND and NEUTRAL connections from Remote Control Receiver to Terminal Block. Plug the 9‐Pole plug connector from the DC Motor into the 9‐Pole plug connector from the Receiver. NOTE: ensure that the 9‐pole connector is fully engaged! If not connected correctly the motor may rotate “jagged” or not rotate at all.
AerAtron >> Silent Efficiency Remote Control Set‐up Code match your transmitter and receiver Note: receiver itself does not need to set DIP switch. Speed Remote Control Code Setting Set your Dip Switch to control individual fan(s) (one per fan handset) and only power one fan per time. Chose same code setting for up to 16 fans controlled by one handset within a 7m radius with power to all fans.
AerAtron >> Silent Efficiency Attaching Fan Motor Housing to Motor Assembly Line up fixing hole in Motor Housing with screw hole in chassis and install screw Install motor housing using a clockwise Bayonet action Ensure that Fan Motor Housing fixing point with hole (not bayonet slot) is aligned with chassis arm from which fixing screw was removed (see page 6).
AerAtron >> Silent Efficiency Fan Blades and Middle Piece Assembly ! CONSTANTLY HANDLE FAN WITH CARE AT ALL TIMES TO AVOID DAMAGING THE FAN/SURFACE ! e502 Place e502 Hub Upper onto a clean working area. Line‐up the three mounting holes in the e500 Fan Blade with the two screw boss and hole in the Hub Upper.
AerAtron >> Silent Efficiency ! CONSTANTLY HANDLE FAN WITH CARE AT ALL TIMES TO AVOID DAMAGING THE FAN/SURFACE ! e503 Place e503 Hub Upper onto a clean working area. Line‐up the three mounting holes in the e500 Fan Blade with the two screw boss and hole in the Hub Upper.
AerAtron >> Silent Efficiency Fan Blades to Shaft Assembly Pivot Screw Rotate Screw Cover to hide screw head. (Note: Rotating the Screw Cover will prevent Pivot screw from falling out should it become loose.
AerAtron >> Silent Efficiency Technical specifications e503 and e502 Colour: white/ silver/ black Remote control: Hand Held, RF Dimensions: e502 as e503 Operating speed (rpm)/ Power Usage (Watt) e503 Speed 1: 51 rpm/ 3.8 W Speed 2: 70 rpm/ 4.5 W Speed 3: 103 rpm/ 7.5 W Speed 4: 119 rpm/ 9.5 W Speed 5: 139 rpm/ 13.6 W Speed 6: 158 rpm/ 18 W e502 Speed 1: 52 rpm/ 3.9 W Speed 2: 73 rpm/ 4.5 W Speed 3: 113 rpm/ 7.7 W Speed 4: 131 rpm/ 9.6 W Speed 5: 153 rpm/ 13.6 W Speed 6: 177 rpm/ 18.
AerAtron >> Silent Efficiency Sloped Ceiling IF THERE ARE ANY PROBLEMS DURING INSTALLATION OF THE FAN, THE INSTALLER MUST CONTACT THE AERATRON HELP LINE BEFORE LEAVING THE SITE: SWISS PRECISION +61 410 465 228 Installation - Operation – Maintenance - Warranty 15
AerAtron >> Silent Efficiency Care & Cleaning Regular cleaning of the Aeratron Ceiling fan blades and fan motor housing is the only maintenance that is needed. Due to the self‐balancing design, a large build up of dust on blades may only in extreme cases create an imbalance, causing the blade to wobble during use. This is likely to be more apparent on fans with an extension rod. Regular cleaning of the blade is recommended to prevent dust from building up. 1.
AerAtron >> Silent Efficiency General Information 1. All electrical motors, including fan motors make some noise, and may feel hot to the touch. This is NOT a fault. 2. Ceiling fans tend to move during operation due to the fact that they are not rigidly mounted. (Rigid mountings can generate excessive vibration and stress on the mountings). Movement of a couple of centimetres is quite OK and does not suggest that the fan will fall down.
AerAtron >> Silent Efficiency Balance of Warranty on Repaired or Replaced Products. Any replaced or repaired product is covered only by the balance of the warranty remaining on the original article. Transfer of Warranty. If the dwelling where the fan or remote control is installed changes hands, the balance of the warranty passes to the new owner, providing the original bill of sale for the product is retained by the new owner.
AerAtron >> Silent Efficiency WARRANTY PHONE NUMBER +61 2 93656470 (AUSTRALIA ONLY 9am to 5pm East) Please Note: When phoning for warranty you will require the following information; date of purchase; model and colour of the fan. The installing electrician’s details may also be required.
AerAtron >> Silent Efficiency Thank you! Your AerAtron team Australian edition 2012.