• You can monitor the status of the call on the screen:
o CALLING.
o CONNECTING (depending on the communication interface and the network
status, this may be a status of extremely brief duration).
o SYNCHRONIZING (depending on the communication interface and the network
status, this may be a status of extremely brief duration).
o CONNECTED.
• Verify that the “SYNC“ LED beneath the “CALL“ button is lighted in green to indicate
that the communication has been successfully established.
• Press the “ON AIR“ button to enable audio transmission in full duplex mode.
• Once the connection has been established with the remote end, confirm the presence
of transmitted and received audio by checking the audio presence indicators “Tx” and
“Rx”.
• If necessary, adjust the output levels in the “att” box at OUTPUTS block in
“Configuration” Æ ”General” screen. You can also make an additional adjustment from
the windows you access by pressing “In gain” button in “ENCODER” green window and
“Out gain” button in “DECODER” green window.
NOTE: In order to make calls to multiple destinations, please consult section 3.2.3.1 of this
manual.
4.5.1.1. Finalizing an IP communication in RTP mode.
• To finalize the communication, simply press the “CALL“ button in the individual codec
control window and then confirm. Repeat the process in the unit at the other end.
4.5.2. Establishing an IP communication in PROXY SIP mode.
• Ensure that the equipment is powered up and controlled by the software.
• Establish the appropriate audio configuration (analog/digital input mode, gains, routing
of inputs to the codec, suitable encoding).
• Check that there is incoming audio: the “Tx“ indicator in the individual codec control
window
, in the general configuration screen and in the list
view
will change to green .
• Go to general configuration screen and configure “INTERFACE” as “Net1 SIP, Proxy
based”:
• Then the equipment tries to register in the defined SIP server (“REGISTERING”). When
the process is done correctly “REGISTERED” indication will be shown and the call can
be made; if not, “REGISTRATION_ERROR” indication appears: in that case, you must
check the unit’s configuration as indicated in the following steps.
• Enter “I/F Setup“ and click on “SIP
Parameters”.