User`s manual

EAGLE - ANNEX A.6. Installation of the EAGLE as an ISDN hybrid.
72
Connection of an EAGLE to an AEQ BC-2500 MIXER:
In order to connect an EAGLE to a BC-2500 Mixer for using the hybrid features, module
BC2533 is used. It is possible to connect the EAGLE to one BC2533 or two BC2533.
Connection of an EAGLE to ONE BC-2533 channel:
In this configuration, with two BC2533 and two EAGLES, there can be up to 4 calls in
conference.
As the BC2533 has only one audio input and output, it will be connected to EAGLE first line.
The EAGLE has to be set to MULTIPLEX. This way it is possible to have 2 communications in
conference though this module.
In order to configure remote control, the following programming bridges of the BC2533 has to be
set:
PDP 7 and 10: ON
PDP 8, 9, 11 and 12: OFF (removed)
Control cable pinout would be: