EAGLE - ANNEX A-5 ISDN BACKUP FACILITY.
70
The EAGLE will monitor v.35 clock signal and will stop ISDN communication and re-start to
restore main v.35 connection five seconds after it detects v35 clock signal is again in the
interface.
The V.35 connection has the higher priority because the ISDN is used only when the
main connection fails.
The EAGLE that receives the call has to be configured as automatic off-hook.
In order to test that backup system works, we recommend to turn off v.35 terminal.
Never disconnect v.35 connector when the equipment is on.
In case that the test is not succesfully, check the following:
- make sure that both audiocodec work fine when connected in the V.35 line.
- make sure that both audiocodec work fine when connected in the ISDN line.
- make sure that both audiocodec detect the line failure.
- make sure that both audiocodec have the same firmware versions and these accept
the backup facility. Version must be higher than MCU 2.20 / DSP 1.10 / TA 4.09