User`s manual

EAGLE
Multi-Standard Dual-Channel Digital Audio Codec
16
Automatic startup configurations are created in the SETUP section, using the keypad (no. 9) on
the Front panel and the LCD (no. 1).
- On the main screen, press NO (red) to access the SETUP menu.
- With the cursor arrows, scroll to the STARTUP option and press OK.
- Complete the following diagram using the cursor arrows:
(1) Name of startup configuration. Names are introduced through the alphanumeric keyboard.
(2) ISDN Number to call in automatic way. This field will be empty if no number has to be
dialled. AUTO CALL (6) has to be ON to enable call generation.
(3) Encoding type to use.
(4) Configuration of the status the audio channel will have when synchronized:
NONE: no audio output, channel is muted.
WAIT: the remote equipment or caller does not go on air, but is able to receive a return
signal. “WAIT” button will be active.
ON AIR: the remote equipment or caller receives the return signal and is placed on air.
“ON AIR” button will be active.
COMM: activates the unit’s intercom, so the remote will only communicate with the
intercom operator. “COMM” and “MON” buttons will be active.
(5) Monitoring feature active when power up.
(6) Automatic call generation activation and automatic recall when line cuts off.
(7) Multiplexing between the two channels
STARTUP Nº CONFIG
LINE2
AUTO CALL
MULTIPLEX (7)
LINE 1
LABEL (1)
ANALOG CONFIG (4)
MONITOR (5)
NUMBER (2)
CODIFICATION (3)
ON
OFF
COMM
ON AIR
WAIT
NONE
G722 STAT
.............
MPEG LII 256
MPEG LII 256
ANALOG CONFIG
MONITOR
CODIFICATION
NUMBER
ON AIR
COMM
WAIT
NONE
.............
G722 STAT
AUTO CALL (6)
ON
ON
ON
OFF
OFF
OFF